Kozy-World 

®

 

   

 

   

20-6030 BLOWER 

ACCESSORY INSTALLATION 

INSTRUCTIONS

 

   

   

   

   

   

   

   

   

   

   

WARNING:  ELECTRICAL  GROUNDING  INSTRUCTIONS  This 

appliance  is  equipped  with  a three-prong (grounding) plug  for  your 
protection against  shock  hazard and should  be plugged  directly into 
a properly grounded three-prong receptacle.

 

   

   

Questions about  installation, operation, or troubleshooting?

 

Before retur ning to your retailer, call KOZY WORLD at 1-800-

776-9425.

 

Summary of Contents for 20-6030

Page 1: ...This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Questions about installation operation or troubleshooting Before returning to your retailer call KOZY WORLD at 1 800 776 9425 ...

Page 2: ...ture Sensor 1 D XB004 01Q Connect Wire 1 E PF06 0400 A Rocker Switch 1 Hardwar e Item Part No Description Qty AA GB T 845 4 2 9 5F M4 2x9 5 Screw 6 BB VL057 01 Cable Tie 6 CC GB T 845 4 2 9 5 M4 2x9 5 Screw 4 AA BB CC If any of these pieces are missing or damaged contact the dealer where you purchased this kit or World Marketing of America at 1 800 776 9425 for referral information ...

Page 3: ...ce turn controls to the off position then remove plug from outlet Connect to properly grounded outlets only This appliance when installed must be electrically grounded in accordance with local codes with the current CSA C22 1 Canadian Electrical Codes or for USA installations follow local codes and the National Electric Code ANSI NFPA No 70 Do not insert or allow foreign objects to enter any venti...

Page 4: ...river Wire Cutter GFD2545 see page 4 GSD3033 GFD4360 and GSD4400 see page 8 BLOWER INSTALLATION GFD2545 Protection Tab Install Blower Top Cover Install Power Cord and Grounding Terminal Install Temperature Sensor to Back of Firebox after Removing Top Cover Install Rocker Switch ...

Page 5: ...m page 15 Be sure to insert the gasket between the protection tab and the grounding terminal see Figure 4 AA Grounding Terminal Gasket Protection Tab Figure 4 Installing Grounding Terminal to Top Cover 5 Insert the blower connector male port into the female port on the wire connector This protects the jacket in the fireplace see Figure 5 Male Port AA Female Port Figure 2 Installing Power Cord 3 At...

Page 6: ...Insert the wires marked with AUTO OFF and MAN into wire slot in the right corner Feed them as close to the bottom of the firebox as possible see Figure 10 Figure 7 Connecting P2 Wires 8 Bundle the wiring with the cable tie BB Attach cable tie to the top panel through the hole as shown in Figure 8 This is to avoid any heat damage to the insulation board Install End of Cable Tie Through Hole BB MAN ...

Page 7: ... Feed the AUTO OFF MAN connectors through the rocker switch hole on the left side of the control panel see Figure 14 Figure 14 Inserting Rocker Switch Wires Figure 15 Connecting Wires to Rocker Switch 17 Push the rocker switch into the control panel see Figure 16 Figure 16 Installing Rocker Switch 18 Reattach the control panel with two screws removed in step 14 see Figure 13 19 Reinstall logs acco...

Page 8: ...d Grounding Terminal Install Rocker Switch GSD4400 Install Temperature Sensor Install Install Blower Wiring and Grounding Terminal Install Rocker Switch Install Rocker Switch GFD4360 Install Blower Install Temperature Sensor Install Wiring and Grounding Terminal Install Rocker Switch ...

Page 9: ...INSTALLATIO N 8 www worldmkting com 200071 01A ...

Page 10: ...ower to the inside of the blower access panel with 4 M4 2X8 screws CC see Figure 19 Figure 21 Attaching Temperature Sensor to Firebox 5 Insert wires marked with AUTO OFF and MAN into wire slot in the right corner of the stove body Feed the wires down and as close to the bottom of the stove as possible see Figure 22 CC Blower Figure 19 Attaching Blower to Blower Access Panel 3 Attach the power cord...

Page 11: ...ite power supply wire marked with P1 into the corresponding male port marked with P1 see Figure 24 Female Port Figure 26 Connecting Blower Wire to Wire Connector 10 Attach the grounding terminal to the tab on the right side of the blower access hole with 1 M4 2X8 screw AA see Figure 27 Figure 24 Connecting P1 Wires AA Grounding Tab 8 Insert the male port which is on the black power supply wire mar...

Page 12: ...ket and control panel see Figure 31a GSD4400 Remove screws securing con trol panel see Figure 31b GFD4360 Remove screws securing con trol panel see Figure 31c Cable Tie Fixed Hole GSD4400 Shown Figure 29 Securing Blower Wires 13 GSD3033 Remove 2 screws securing grill to stove front Carefully set grill aside see Figure 30 GSD4400 Rotate handle and open the door Figure 31a GSD3033 Log Bracket and Co...

Page 13: ...e 33 AUTO OFF O 18 Push the rocker switch into the control panel see Figure 34 Figure 34 Installing Rocker Switch 20 Reattach the control panel and log bracket if applicable with screws removed in step 15 see Figure 31 page 11 21 Reinstall logs according to original layout Refer to owner s manual for log place ment 22 GSD3033 Replace grill with 2 screws re moved previously see Figure 30 page 11 Fo...

Page 14: ...o not coil or cover the extension cord WARNING Electrical outlet wiring must comply with local building codes and other appli cable regulations to reduce the risk of fire electrical shock and injury to persons WARNING Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical syste...

Page 15: ...ee movement and for debris restricting air flow If the fan does not move freely the unit must be turned off and the fan replaced immediately in order to prevent further dam age to the unit REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t...

Page 16: ...and or in Canada with the current CSA C22 1 Canadian Electrical Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 Bushing Strain Relief WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing color coding and secur ing locations must be followed 120V 60Hz Power Cord WHITE GREEN BLACK RED AUTO OFF MAN Rocker Switch Temperature Sensor...

Page 17: ...del Serial No Date Purchased Keep receipt for warranty verification Kozy World World Marketing of America Inc PO Box 192 Rt 22 West MillCreek PA 17060 www worldmkting com 800 776 9425 200071 01 Rev A 06 13 ...