Kozy Power Vent #KPV
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
3
1.1 Introduction
The #KPV is certified for use as a horizontal termination cap only for
use with the Callaway-72 direct vent fireplace.
Control system configurations:
•
The battery-backup feature cannot be used with #KPV
•
The wired wall switch feature cannot be used with #KPV
•
An appliance with #KPV installed cannot be operated with
battery back-up or a wired wall switch
The #KPV operates on 120VAC, 60Hz electrical service which is
supplied at the fireplace junction box. The current draw of this device
is 0.85 amperes.
The following vent pipe manufacturers are approved for use with
the Kozy Power Vent:
American Metal Products (Ameri-Vent), BDM,
ICC, Metal Fab, Olympia Chimney Supply, Inc., Selkirk, and Simpson
DuraVent.
IMPORTANT OPERATIONAL NOTE: When the control being used to run
the fireplace is activated, there will be up to a 120 second delay before
pilot ignition will begin. This is to allow a pre-ignition purge by the
#KPV. If after 135 seconds the pilot and burner do not light, refer to
Section 6.0 on page 21 of this manual. There will be also 120 second
post-operation purge in which #KPV will continue to run after the
appliance is turned off.
NOTE: The fan motors present in this power vent will generate sound
during operation. The effects of the increased sound level can be
minimized with careful planning during installation of the system.
1.2 Components and Service Parts List
1.2.1 Service Parts List
Replacement Parts can be obtained from your local dealer. Repair of
the #KPV should only be done by a qualified service technician.
•
#KPV-101
Fan Assembly
•
#KPV-102
Vacuum Switch
•
#KPV-103
Vacuum Tube
•
#KPV-104
Cover Assembly
1.2.2 Power Vent Wire Harness - Required
The wire harness connecting the #KPV to the appliance is sold
separately. The length of the wire harness needed varies by
installation.
•
10 ft pv wire harness
•
20 ft pv wire harness
•
40 ft pv wire harness
•
60 ft pv wire harness
•
80 ft pv wire harness
•
100 ft pv wire harness
1.2.3 Optional Components
•
Power Vent Finishing Extension Kit: #KPV-FEK
1.3 Installation
1.3.1 Installation Precautions
•
This device must be installed by a qualified installer in
accordance with these instructions.
•
Safety inspection of the venting system should be performed
before and after installation of this power vent. Installation of
the Kozy Power Vent must comply with local, regional, provincial,
state, and national codes and regulations.
•
DO NOT INSTALL DAMAGED EQUIPMENT OR VENT COMPONENTS
•
Disconnect electrical power supply before making wiring
connections.
•
Venting of more than one appliance in a common vent system is
prohibited.
•
Clearances between the vent pipe and combustible materials
must be maintained.
•
WARNING: Failure to install, operate, and maintain the power
venting system in accordance with manufacturer's instructions
will result in conditions which may produce bodily injury and/or
property damage.
1.3.2 Installation Guidelines
•
The exit termination of mechanical draft systems shall not be less
than seven feet above grade when located adjacent to public
walkways.
•
A mechanical drafting venting system shall terminate at least
three feet above any forced air inlet located within 10 feet.
1.3.3 Painting Requirements
The #KPV may be painted to a desired color, as long as the paint
selected has sufficient temperature and environmental ratings.
•
Thoroughly sand the existing coating prior to painting with
sandpaper or steel wool.
•
The front of the cap cover may be field-painted and cured up to
400 degrees Fahrenheit (204° C). All remaining parts of the cap
may be painted but they may not be cured beyond 190°F (88°C)
due to gaskets and components overheating.
•
Certain areas of the cap surface may reach up to 600° F (316°C).
Paints selected should have sufficient temperature ratings.
•
Cap contains silicone sealant which could affect adherence of
paint. Please advise local painter of silicone content.
1.0 INTRODUCTION