![Koyoe KY-EST06KH User Manual Download Page 76](http://html1.mh-extra.com/html/koyoe/ky-est06kh/ky-est06kh_user-manual_1999590076.webp)
76
Pin
Name
Type
Describe
define
max value
A4,A9,B4,B9
VCC
Power Supply
DC 5V~12V
DC5V
– 12V
DC
-
0.3V~16V
A1,A12,B1,B
12
GND
Ground
DC 0V
DC 0V
DC -0.3V
A6,B6
RS485-A
RS485 A line
-
-
-7V
≤
VCM
≤
+12V
A7,B7
RS485-B
RS485 B line
-
-
Be careful!
-Please connect RS485 in the correct line sequence.
-If the customer needs RS485 to communicate with the inverter,
it is necessary to purchase a USB to RS485 converter.
11.3 RS-485 Communication
1.Through the purchase of type-C cable, transfer to 485 to USB communication line, and
then connect to the computer.
2.Through the purchase of type-C cable, it is connected to the third-party RS485 to
Ethernet switch.