Page 1: ...USER MANUAL www kovan ba Automatic fireplace on pellets EKO LINE INSTALLATION USE AND MAINTENANCE ...

Page 2: ...ir air in the premise 11 5 Information about the fireplace 11 5 1 Quality statement 12 5 2 Fireplace type 12 5 3 Technical information 13 5 4 Fireplace description 14 5 5 Applied regulations 15 5 6 Scope of delivery 15 6 Fireplace installation 15 6 1 Important instructions 16 6 2 Selection of the mounting location 16 6 3 Chimney connection 17 6 4 Preparing for installation 17 6 5 Electrical connec...

Page 3: ...ts 33 8 2 Cleaning of outer mantle 33 8 3 Cleaning of the furnace 34 8 4 Cleaning of the glass 34 8 5 Exchange of door glass 34 8 6 Annual maintenance cleaning 35 8 7 Period when the fireplace is not in use 36 9 Device errors 36 9 1 Smoke pipe system error 36 9 2 Error of motor for pellet input 36 9 3 Activation error 36 9 4 Break in supply of electrical energy 37 10 List of disorders their causes...

Page 4: ...ne fireplace A modern quality and highly efficient product which ensures the largest comfort of heating on a long period of time by its reliability and safety The maintenance is simple and it can be performed personally and easily as well as it can be confide to Technical service of manufacturer Kovan whose servicemen are trained for the maintenance of fireplaces and if necessary they have all the...

Page 5: ...d conditions of warranty The warranty is a part of this product and its value is conditional by readable and filling up true data in it We recommend you to confide putting the fireplace into operation to a professionally trained individual or contact our Technical Service Kovan who will on your request put the boiler into operation in manner that is specified by this manual Obligatorily before und...

Page 6: ...alling the device The fireplace must be only intended for use and purpose which is specified by the manufacturer and for which it has been constructed Kovan m i excludes any liability contractual or non contractual for the incurred damage to people animals or objects due to errors at the installation regulation and the maintenance and due to the inadequate use Maintenance of the boiler must be per...

Page 7: ...evice and in accordance with that it is prohibited to touch it barefooted or with wet body parts It is prohibited to interven or to clean the fireplace while it is plugged into electrical supply or before it has been shut off by setting the selector of functions on off It is prohibited to adjust the fireplace safety appliances or regulators without instructions and permits from the manufacturer It...

Page 8: ...tes that minor material damages can appear Warning means that minor injuries or heavy material damage can appear Danger means that severe injuries can emerge In particularly severe cases exists danger for life Remarks contain important information in cases when there is no threat of any danger for the man or the boiler Instructions for safe work are marked with a warning triangle Remarks in the te...

Page 9: ... closed and sealed Possible additional openings on the chimney door for cleaning and possible spare openings should also be closed and made sure they will not self open because of the increased pressure of the gases in the chimney During burning and later after self quenching and cooling the chimney should be constantly monitored and all noticed critical spots should be controlled It is strictly f...

Page 10: ...d the environmental acceptability of the installation Use only original spare parts recommended by the manufacturer 4 5 Combustion air air in the premise Do not close nor reduce the air hole and ventilation If the premise has airtight windows ensure the supplying of combustion air Combustion air air in the premise maintain without aggressive substances e g halogenic hydrocarbons which contains com...

Page 11: ...on with the materials of which the fireplaces were built were carried out in a specialized laboratory for testing materials and structures Rudarski institut d d Tuzla About all this we have the correct documentation and quality reports Ensuring product quality guarantees our implementation of the approved quality system for production final inspection and testing TÜV cert 15 100 7505 4 in accordan...

Page 12: ...lace type EKO 1 7 5 Width depth height cm 75 59 131 Weight kg 105 Tube air entrance mm 60 Tube fume exit mm 80 Heating capacity m 2 70 Operation autonomy sat 10 Nominal thermal power kW 7 5 Fuel type Wood pellet 6mm Fuel consumption min max kg sat 0 75 2 4 Percentage of efficiency 90 Storage capacity kg 16 Consumption of electrical energy W 60 Voltage V Hz faza AC 230 50 1 Driving voltage V DC 12 ...

Page 13: ... and then pressed by another wave of flue gas move to another space exchange chamber The mantle of the chamber is a barrier around which the flue gases move exchanging their temperature which is at the other side taken by the ventilator and spread around the room This enables the warmth to be most efficiently used before it is vacuumed into the funnel The furnace is constructed as a compact module...

Page 14: ... fireplace following directives and regulations are applied Construction of the fireplace is harmonized in compliance with European directives 98 37 EC 97 23 EC and European standards EN 292 1 1991 EN 292 2 1991 EN 12952 2 EN 12952 3 EN 12952 4 EN 12952 5 EN 60335 2 BS EN 292 1 1991 Safety of machinery Basic concepts general principles for design Basic terminology methodology BS EN 292 2 1991 Safe...

Page 15: ...act a qualified service person or the manufacturer Make sure that the pellets you are using have the required quality standards It is strictly prohibited burning and incineration of waste and any other combustible materials in the fireplace It is strictly forbidden to add fuel in liquid form Never open the door while the fireplace is in operation During the operation the glass and other parts beco...

Page 16: ...laced on a flat and incombustible surface You should leave the installation to a competent person While setting and installing the device it is important to follow certain standards and international norms In cases when rules or regulations collide please follow the national norms Safe and economic operation of the fireplace will be ensured if the installer follows the given instructions and regul...

Page 17: ...n find the corresponding instructions and the guarantee card Place the fireplace on the planned installation location Connect the fireplace to the chimney so that there s allowed a slight drop to the fireplace or a horizontal position Connect the fireplace to electrical supply 6 5 Electrical connection DANGER OF ELECTRIC STRIKE Before work on electrical parts the boiler must always be turned off f...

Page 18: ...e of the boiler ensure a connecting place with a 1 phase outlet The place of the outlet should be properly selected so that the socket device is always easily accessible Danger In case of damage to the power cable it is necessary to replace it with a correct cable Cable replacement should be delegated to a competent person or to the producers service ...

Page 19: ...Improvisation and patching of the fuse is strictly forbidden Note Electrical connection must match the current regulations for electrical installations in households You must have a protective conductor In the case of a direct power cable connect it is necessary to install a switching device that provides a reliable turning off of the fireplace The distance between the contacts of the device shoul...

Page 20: ...hat is the procedure which depending on the fireplaces working mode lasts for a few minutes After the switcing off process when displaying OFF on the display the fireplace can also be physicall separated from the electrical power source 6 6 Putting into operation Check if the type of pellet described in this manual matches the type of pellet in your storage The storage can be filled to the top wit...

Page 21: ...s three operating modes P1 P2 P3 These three operating modes enable easy set up of the fire to the needs of users Settings on the operating mode P1 P2 P3 are set up so that there are three levels of fire size and thus determines the speed with which the space heating up Warning Never open the fireplaces door while it is still in function ...

Page 22: ...ce has an automatic ignition process The burner needs to be cleaned before every start of the fireplace In cases of first ignition or ignition after the disappearance of pellets is necessary to put a handful of pellets into the burner After the ignition process the fireplace switches to ON The display shows the active mode ...

Page 23: ...USER MANUAL www kovan ba 23 Parameters that are needed to be changed for P1 mode are To change the value press the button and change it with the and buttons ...

Page 24: ...USER MANUAL www kovan ba 24 Parameters that are needed to be changed for P2 mode are To change the value press the button and change it with the and buttons ...

Page 25: ...USER MANUAL www kovan ba 25 Parameters that are needed to be changed for P3 mode are To change the value press the button and change it with the and buttons ...

Page 26: ...ton to confirm Regulation of fuel ammount and air needs to be set up for every pellet individually By the visual control of the flame you can add or subtract air in the burning If the flame has black smoke and or the glass of the fireplace turns black then its necessary to increase air If the flame is white and or the glass of the fireplace turns white there is a need to reduce the air This needs ...

Page 27: ...unctions 7 4 1 Hysteresis Difference between the current and wanted temperature before re firing 7 4 2 Cleaning period The period of cleaning the burner of the fireplace depends on the quality of pellets This period is on average 15 minutes ...

Page 28: ...USER MANUAL www kovan ba 28 7 4 3 Cleaning duration Duration of burner cleaning The duration is on average 15 seconds 7 4 4 Language Languages that can be used English Bosnian German Slovenian ...

Page 29: ... www kovan ba 29 7 4 5 Input phone Enables to switch on the fireplace via telephone If you don t have installed this device you must set its value to disabled 7 4 6 Clock Is used to set up the current day and time ...

Page 30: ...e the timer then you have the choice of the following options Election of the day Mon Sun Adjustment is made for each day separately Mon Sun Adjustment is made for a whole week Mon Fri Adjustment is made for Monday Tuesday Wednesday Thursday Friday Sat Sun Adjustment is made for Saturday and Sunday First start of the fireplace 1 START Sets the time to start the fireplace First stop of the fireplac...

Page 31: ...n set it to 24 00 8 Cleaning and maintenance During the burning process in the burner remain fireproof substances like sand which can be find in the pellet Since the pellet burns down on high temperature sand melts and unites in larger pieces of scoria Scoria fulfills the space in the burner and obstructs the process of burning and the fireplace starts to smoke which is a sign to clean it Only whe...

Page 32: ...ponents of the fireplace use a wet cloth or proven products for cleaning of metal components Warning Before you clean the fireplace disconnect it from voltage Unplug the supply cable or turn of the breaker if the fireplace is equipped with an inseparable cable i e if it is directly connected Alert The vacuum cleaner is meant for a special purpose The inner part of the cleaner is made of metal and ...

Page 33: ... is extremely red and hot and the flame seems to be too small or is accompanied by dark smoke this means that there is an increased amount of slug in the furnace which hinders fresh air circulation which can lead to extinction of fire in the fireplace If the fire extinct every day the furnace has to be cleaned with the right equipment This needs to be done especially during the few first times the...

Page 34: ...ould check if the sealing joint at the borders of the glass is in good condition A bad condition of the sealing joint could cause problems connected with the functioning of the fireplace 8 5 Exchange of door glass The fireplace is equipped with ceramic glass 4 mm of thickness that resists a thermal shock of 750 degrees of Celsius It could only be broken by a hard beat or inadequate handling of the...

Page 35: ...ng of mechanical components motor and ventilator Exchange of igniters 8 7 Period when the fireplace is not in use At the end of each season when the fireplace is no longer in use it is recommended to clean the fireplace in detail Note We advise you to have the fireplace checked before each heating season by a competent person For safety reasons it is important to regularly maintain the fireplace ...

Page 36: ...ues to work until all pellets in the storage are spent After that the fireplace stops its activity 9 3 Activation error In case there is no flame during the activation process an activation error will be displayed 9 4 Break in supply of electrical energy In case that there is no supply of electrical energy all devices stop working and in the next three to five minutes a minimal dosage of fume coul...

Page 37: ...USE HANDLING Alarm Fume sonde 1 Faulty smoke probe 2 Break in the communication disconnected cable 1 Request assistance from authorized person 2 Request assistance from authorized person Note In cases of increased voltage supply the fireplace is ensured with a breaker The electrical connection has to be grounded The producer hedges against all damage due to incompetent handling or embedding of ele...

Page 38: ...orm spindle 5 Faulty electrical lighter indication cold burner 6 Bad pellets all previously mentioned causes excluded and there s still no ignition 1 Fill up the pellets tank 2 Clean the burner 3 Clean the flue tubes 4 Shake up the pellets reset the alarm and start the fireplace again 5 Request assistance from authorized service 6 It is necessary to adjust the function of burning and dosing 7 In c...

Page 39: ...ed and there s still no ignition 4 3 Changed parameters of service functions or they re adjusted over the limitation 5 The door is not closed 1 Fill up the pellets tank 2 Clean the burner 3 Clean the flue tubes 4 1 Shake up the pellets reset the alarm and start the fireplace again 4 2 Replace the pellets with pellets of appropriate quality 4 3 Check the settings and if necessary rerun the adjustin...

Page 40: ...lets quality 1 Clean the burner and the flue tubes 2 Check the pellets and correct the delivery of pellets through the service function dosing the burning 3 Consult the manufacturer about possible solutions Smoke comes out of the pellets tank 1 Dirty flue 2 Bad pellets quality 3 Chimney doesn t have necessary buoyancy 1 Clean the flue 2 Correct the amount of air in the function menu 3 Close possib...

Page 41: ... The fireplae stopped working and the display is turned off 1 Error in power supply 2 Burned fuse on the electronic module 1 Provjeriti napajanje 2 Exchange the fuse with an original one 2 1 In the case of re burning the fuse ask for help from an authorized service Problems due work because of the increased accumulation of scoria in the burner 1 Very bad pellets 1 Contact the supplier of manufactu...

Page 42: ...in the pellets 1 Contact the supplier of manufacturer of pellets 11 Instructions for quality evaluation of pellets during the purchase When buying pellets from the distributors or manufacturers require the declaration of testing and proving quality The form of pellets must be compact uniform sizes by diameter φ 6 mm It is important to know that wet pellets can easily crush between your fingers ...

Page 43: ... package Ask the dealer for warranty from the pellet manufacturers in terms of absence of foreign impurities in the pellet Impurities that get into the pellet during the production as a result of errors in the processing cause a large part of the previously mentioned problems during burning acceptable ash content 1 Before buying check the weight of packaging in relation to the declared weight on s...