TROUBLESHOOTING
ERROR 003 300…C
ERROR 004 ###…C
ERROR 016 ###…C
1.1.1 300°C
The temperature sensor circuit is open circuited or the PT1000 sensor is not connected or defect.
1.1
Error 004
Occurs only if the SET ALARM parameter is set.
The temperature alarm is activated.
A too high or too low print temperature deviation from the SET TEMP parameter value (±5°C, ±10°C or ±15°C) has
occurred.
The actual print temperature is displayed, here represented as ###°C.
1.1
Error 016
The print temperature algorithm does not detect a temperature change while the heating elements are switched on.
Perhaps the heating element(s) or PT1000 sensor are not connected or defect, the fuses F1/F2 are blown or the heating
circuit is defect.
The actual detected print temperature is displayed, here represented as ###°C.
1.1
LCD screen is not lit
Check the fuses F1, F2, F3 and F4. See Installation chapter.