Reference Guide
99
Reference Guide
Program
Parameters
1
16A–21A Effects
Effects are explained fully in “Effect Parameters” on page 115.
Effects settings made in Program Edit mode only apply to Programs in Program Play mode and
Program Edit mode. They do not apply when Programs are used in Combinations or in Multi
setup. Effect settings for Programs used in Combinations are set in Combination Edit mode. For
Programs used in Multi setup, they are set in Multi mode.
Program parameters Pan A, Pan B, Send C, and Send D are used to control the levels of the
oscillator signals sent to the effects.
When you’ve edited a Program’s effect settings, always remember to write the Program.
Otherwise, the settings will be lost when you select another Program.
22A–22B Program Write & Rename
When you’ve edited a Program’s effect settings, always remember to write the Program.
Otherwise, the settings will be lost when you select another Program.
This function allows you to write a Program to Program bank A. This function can also be used to
reorganize Program numbering by writing Programs to different destinations. You cannot write to
the G bank. You can also rename Programs.
22A Program Write:
To write a Program, specify the write destination, position the cursor on OK?, then press the [
▲
]
button. The message “Are You Sure OK?” will appear. Press the [
▲
] button to write the Program,
or the [
▼
] button to cancel. If you write the Program, the destination Program will be selected
automatically. When the Write operation is completed, the screen displays “Completed.” To return
to the previous screen, press the [
▲
] button or the [
▼
] button.
22B
Rename: This function allows you to rename Programs.
To rename a Program, use the [
√
] and [®] cursor buttons to position the cursor, and the [
▲
] and
[
▼
] buttons to select characters. Available characters are shown in the table below. Program names
can be up to 10 characters.
LCD
Parameter
Range
Description
22A
Write
→
xx
00–99
Select the Program write destination
OK to Write
OK?
Executes Program write
22B
Rename
See character table
below
Rename a Program
Note: To write a Program, the Program Memory Protection function must be set to OFF. See “3A
– 3C Program/Combination Memory Protect & Page Memory” on page 153.
Note: The Program that already exists at the selected write destination will be lost when you
execute the Program Write function.
22A PROG WRITE ø
Write‡ 00
OK?
22A
22B
22B RENAME
X
00:Ephemerals
ø
!
"
$
% & ’
-
.
/
0
1
2
3
4
5
6
7
8
9
:
;
<
=
> ?
(
)
*
+
,
#
@ A B
C
D E
F
G H I
J
K L
M N O P
Q R
S
T
U V W X Y Z
[
‰ ]
^
_
a
b
c
d
e
f
g
h
i
j
k
l
m n
o
p
q
r
s
t
u
v
w x
y
z
(
)
‡
†