System Ver. 1.6 Update Guide

Thank you for choosing the Korg MR-2000S 1-bit studio recorder. 
This update adds new functionality that makes the MR-2000S even easier to use.

1. MR Control Link function

The newly added MR Control Link function lets you perform
synchronized recording and playback using multiple MR-
2000S units.

Connections

Use a S/P DIF cable to connect the S/P
DIF Output of the master MR-2000S
unit to the S/P DIF IN jack of the first
slave MR-2000S unit.
In the same way, connect the first slave
unit's S/P DIF OUT jack to the second
slave unit's S/P DIF IN jack, and the
third slave unit's S/P DIF OUT jack to
the fourth slave unit's  S/P DIF IN jack.

Settings

In the menu screen, select and confirm "SYSTEM," and
then select and confirm "MR Control Link."

In the MR Control Link screen, place a check mark in the
appropriate check box.

Master

• When you use the dial or press a button, a corresponding

synchronization message for that operation will be sent
to all connected MR-2000S units that are set to the "Slave"
setting.

• MR-2000S units that are set to the "Master" setting will

not respond to incoming synchronization messages.

Slave

• The SYSTEM setting "Clock Source" will automatically

be set to S/P DIF.

• If the SYSTEM setting "Input Source" is set to S/P DIF, it

will automatically be set to XLR. You can subsequently
change it to RCA if desired.

• If the SYSTEM setting "Digital Out" is Professional

(AES), it will automatically be set to Consumer (S/P
DIF).(Refer to "9. Digital Out selection" on the other
side of this sheet.)(Refer to "9. Digital Out selection" on
the other side of this sheet.)

• The unit will synchronize to the master MR-2000S unit's

record, play/pause, FF, and REW button operations.

• The dial and buttons of slave MR-2000S units can be

operated, but synchronization messages will not be
transmitted to other connected slave MR-2000R units.

Off

• Synchronization messages will not be transmitted or

received.

Operation

• During recording, the REC mode setting of a slave unit

will be the same as the master MR-2000S unit's setting.

• If you insert a marker on the master MR-2000S during

recording, a marker will be assigned at the same time
location on the slave units as well.

• When you move to a marker on the master MR-2000S,

the slave units will move to the same time location.

• You can move to a marker either during playback or

while stopped.

• If you fast-forward or rewind on the master MR-2000S,

the slave units will move to the same time location when
you release the button on the master unit.

• If you use the dial on the master MR-2000S unit to return

to the beginning of the song, the slave units will also
return to the beginning of the song.

 

Be aware that if you pause the master MR-2000S unit 
during recording, the slave units will not be at the same 
time location.

2.  Selection of stereo or mono as the 

recording format

After you select and confirm "REC MODE" in the menu
screen, turn the dial to add a check mark to the desired check
box of the Stereo/Dual Mono screen.

If you select "Dual Mono," the L/R audio will be recorded as
separate audio files in the project folder.

Example:

WAV_0001_001_1.WAV
(monaural file for the L-channel input)

WAV_0001_001_2.WAV
(monaural file for the R-channel input)

3. Dual Mono playback of monaural files

When playing a project that was recorded with "Dual Mono"
selected as the recording format, or if there are monaural files
whose name ends in a numeral (e.g., trk1) or that are likely to
be a pair (e.g., _L, _R), they will be played back as a Dual
Mono stereo pair.

If the paired file is not found, that monaural file will be out-
put from both channels.

If the paired file is not found, the same sound will be out-
put from both channels.

4. Level Meter Off setting

In the PEAK HOLD screen of the menu list, you can turn the
Meter setting "Off" so that the level meters (including the
peak LEDs) will not light up.
Choose the "Off" setting if you don't need to check the level,
or if the level meters are too bright for the lighting conditions
in your room. Even in this state, you can view the peak level
of the input/playback audio by looking at the dB indication
on the INPUT LEVEL screen of the menu list.