A.1 Technical data, SO CM-E
ServoOne CM-E expansion module
Unit
SO CM-E.x0xx.0 (2)
(Dual End)
SO CM-E.x0xx.1
Dual
Control section
Supply v/- 10%
V DC
24
24
Rated current consumption
A
0.25
0.25
Power dissipation
W
6.0
6.0
DC link (input = left, output = right side of device)
Input voltage 1)
V DC
565 to 678
565 to 678
Input current
A DC
39 to 33
78 to 64
Output voltage 1)
V DC
565 to 678
565 to 678
Output current
A DC
39 to 33
2 x 39 to 2x 32
Power section
Continuous power P
N
kW
22
44
Peak power 2 x P
N
for 1 s
kW
44
88
Power dissipation in the interior
W
20
20
1) The voltage is dependent on the supply unit SO CM-P and the supply voltage connected (3x400/480 V AC)
Table A.1 Technical data, SO CM-E expansion module
A.2 Ambient conditions
Ambient conditions
ServoOne CM-E expansion module
Protection
Device: IP20 - exception terminals: IP00
Accident prevention regulations
As per the local regulations (in Germany e.g. DGUV V3)
Installation altitude
Up to 1000 m above MSL, higher with power reduction
(1% per 100 m, max. 2000 m above sea level)
Pollution degree
2 (as per EN 60664-1)
Type of mounting
Built-in unit, only for vertical mounting in a switch cabinet with min. IP4x
protection, on using STO safety function min. IP54
Table A.2 Ambient conditions, ServoOne CM-E expansion module
Climatic conditions
ServoOne CM-E expansion module
In transit
As per EN 61800-2, IEC 60721-3-2 class 2K3
1)
Temperature
-25 °C to +70 °C
Relative atmospheric
humidity
95% at max. +40 °C
In storage
As per EN 61800-2, IEC 60721-3-1 classes 1K3 and 1K4
2)
Temperature
-25 °C to +55 °C
Relative atmospheric
humidity
5 to 95%
In operation
As per EN 61800-2, IEC 60721-3-3 class 3K3
3)
Temperature
5 °C to +40 °C (4, 8, 16 kHz), to 55 °C with power reduction
Relative atmospheric
humidity
5 to 85% without condensation
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70 °C for example, that the relative atmospheric humidity may only be max. 40%.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative atmospheric humidity stipulated in the table must
not occur simultaneously.
3) The absolute humidity is limited to max. 25 g/m³. That means that the maximum values for temperature and relative atmospheric humidity stipulated in
the table must not occur simultaneously.