SmartClient-KLU - User Guide, Rev. 1.2
// 25
1.
Depending on the dimension of your SmartClient-KLU, prepare a cutout in the wall / panel. The maximum
thickness of the wall / panel is 6 mm. Refer to Table 1 and Figure 5 for the wall / panel cutout dimensions or to
Figure 12 for the corresponding mechanical drawings of your SmartClient-KLU.
2.
The system must be properly powered down and disconnected from the power source and peripherals.
3.
The wall / panel where you intend to install the system must be accessible from both sides (front as well as
rear). The material strength and stiffness must be sufficient to hold the system unit.
4.
Insert the system into the wall / panel cutout from the front as shown in Figure 5.
Figure 5: Insert the system into the cutout
5.
In order to ensure the protection class IP65 on the front side in the installed condition, the contact surface with
the gasket must be clean and flush.
6.
Remove the mounting opening covers from the chassis with Phillips screwdriver. The number of mounting
openings (Table 1) varies depending on the ordered SmartClient-KLU configuration.
7.
Hook the mounting clamps with screws (Figure 4) from the rear side of the wall / panel into the corresponding
mounting openings as shown in Figure 6.
Figure 6: Hook mounting clamps into mounting openings