6.2.1
Preparing for the Upgrade
The steps below explain how to prepare to upgrade the BIOS, including how to record
the current BIOS settings and how to obtain the upgrade utility.
Note:
In the unlikely event that a BIOS error occurs during the BIOS update process, a
recovery process may need to be followed to return the system to service. See
,
“Additional Information and Software”
for additional information.
6.2.1.1
Recording the Current BIOS Settings
1. Boot the computer and press <F2> when you see the message:
Press <F2> Key if you want to run SETUP
2. Write down the current settings in the BIOS Setup program.
Note:
Do not skip step 2. You will need these settings to configure your computer at the end
of the procedure.
6.2.1.2
Obtaining the Upgrade
Download the BIOS image file to a temporary folder on your hard drive. See
,
“Additional Information and Software”
for additional information.
Note:
Review the instructions and release notes that are provided in the readme file
distributed with the BIOS image file before attempting a BIOS upgrade. The release
notes contain critical information regarding jumper settings, specific fixes, or other
information to complete the upgrade.
6.2.2
Updating the BIOS
Follow the instructions in the readme file that came with the BIOS upgrade. When the
update completes, remove the bootable media from which you performed the upgrade.
Note:
Do not power down the system during the BIOS update process! The system will reset
automatically when the BIOS update process is completed.
Note:
You may encounter a CMOS Checksum error or other problem after reboot. If this
happens, shut down the system and boot it again. CMOS checksum errors require that
you enter Setup, check your settings, save your settings, and exit Setup.
6.3
Clearing the CMOS
If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need
to be used to reset the configuration RAM. The CMOS clear jumper (J1D3) is shown in
Figure 17, “Recovery Jumper Blocks (J1D1, J1D2, J1D3)” on page 33
.
1. Power down the system and disconnect the
power cord.
2. Open the server. See
for instructions.
3. Move jumper (J1D3) from the normal operation position, CMOS Clear by BMC, at
pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3.
4. Wait five seconds.
5. Move the jumper (J1D3) back to the default position (pins 1-2).
6. Close the server chassis. See
“Installing the Chassis Cover”
instructions.
7. Reconnect the power and power up the system.