![Kontron mITX-SSH-S User Manual Download Page 33](http://html1.mh-extra.com/html/kontron/mitx-ssh-s/mitx-ssh-s_user-manual_1996495033.webp)
mITX-SSH-S - User Guide, Rev. 1.0
// 33
7/
Internal Connectors
7.1.
Power Connector
The mITX-SSH-S is designed to be supplied from a +12 VDC power source.
Hot plugging any of the power connector is not allowed.
Hot plugging might damage the board. In other words, turn off main supply etc. to make
sure all the power lines are turned off when connecting to the motherboard.
7.1.1.
DC In 12V Terminal Block (CN1)
Figure 11: DC In 12V Terminal Block CN1
Table 15: Pin Assignment CN1
Pin
Signal
Description
1
GND
2
+12V
7.1.2.
CR2032 Battery Power Input Wafer (BAT1)
Figure 12: CR2032 Battery Power Input Wafer BAT1
Table 16: Pin Assignment BAT1
Pin
Signal
Description
1
2
Battery-