In order to support Intel ® AMT (Management Engine) SLOT A0
must
always be populated. In case of
using more than a single DIMM it is recommended to populate A0 + B0 first.
Fig. 26: Motherboard showing slots for inserting memory
8.6.
Installation in a 19-inch Industrial Cabinet
Expansion card installation should be performed before installing the KISS
Oil & Gas
2U
into an industrial cabinet or into a control panel.
Refer to the
“Installing Expansion Cards” section
Before closing the industrial cabinet, you must connect your peripherals to the
corresponding system ports.
Once all peripherals are connected, position the system in the rack, desktop or control
panel and use the cable tie downs to further secure the system.
Important instructions!
The device must only be incorporated and installed by specialists who are qualified in this
field.
The Widlcat 2U should be installed in a 19-inch industrial cabinet using slide rails unless
reconfigured for desktop usage.
Ensure that air flow around the device is adequate when installing the KISS
Oil & Gas
2U
Ensure that the air inlet and outlet openings are kept clear and free from any obstructions.
Leave at least 5 cm (approx.
2”) of free space to the front and rear of the KISS
Oil &
Gas
2U when installing it from the 19" industrial cabinet, in order avoid possible
overheating.