Standard Removal Procedures
To remove the board proceed as follows:
1.
Ensure that the safety requirements indicated in chapter Safety Requirements are observed.
2.
Ensure that no power is applied to the system before proceeding.
3.
Disconnect any interfacing cables that may be connected to the board.
4.
Unscrew the front panel retaining screws.
5.
Disengage the board from the backplane by first unlocking the board ejection handles and then by pressing the han-
dles as required until the board is disengaged.
6.
After disengaging the board from the backplane, pull the board out of the slot.
7.
Dispose of the board as required.
Care must be taken when applying the procedures below to ensure that neither the CP6940
nor other system boards are physically damaged by the application of these procedures.
Due care should be exercised when handling the board due to the fact that the heat sink can
get very hot. Do not touch the heat sink when installing or removing the board.