2.2
CP6930-1 Initial Installation Procedures
The following procedures are applicable only for the initial installation of the CP6930-1 in a system. Procedures for stan-
dard removal and hot swap operations are found in their respective chapters.
To perform an initial installation of the CP6930-1 in a in a system proceed as follows:
1. Ensure that the safety requirements indicated in chapter Safety Requirements are observed.
2. Ensure that the board is properly configured for operation in accordance with application requirements before in-
stalling. For information regarding the configuration of the CP6930-1, refer to the CLI Reference Manual.
3. To install the CP6930-1 perform the following:
• Ensure that no power is applied to the system before proceeding.
• Carefully insert the board into the slot designated by the application requirements for the board until it makes
contact with the backplane connectors.
• Using both ejector handles, engage the board with the backplane. When the ejector handles are locked, the board
is engaged.
• Fasten the front panel retaining screws.
• Connect all external interfacing cables to the board as required.
• Ensure that the board and all required interfacing cables are properly secured.
4. The CP6930-1 is now ready for operation.
Warning
Failure to comply with the instruction below may cause damage to the board
or result in improper system operation.
Warning
Care must be taken when applying the procedures below to ensure that nei-
ther the CP6930-1nor other system boards are physically damaged by the
application of these procedures.
Warning
DO NOT
push the board into the backplane connectors. Use the ejector han-
dles to seat the board into the backplane connectors.