CP6003-SA
Functional Description
ID 1044-9757, Rev. 2.0
Page 2 - 11
P R E L I M I N A R Y
2.10.2
DIP Switches SW1, SW2 and SW3
The CP6003-SA is equipped with one 4-bit DIP switch, SW1, and two 2-bit DIP switches, SW2
and SW3, which enable the board to be configured according to the application requirements.
DIP Switch SW1 is used for uEFI BIOS boot configuration. DIP Switch SW2 is used for config-
uring the CompactPCI interface. DIP Switch SW3 is used for configuring the PMC interface.
For further information on the configuration of the DIP switches, refer to Chapter 4.1, “DIP
Switches SW1, SW2 and SW3 Configuration”.
2.10.3
USB Interfaces
The CP6003-SA supports six USB 2.0 ports: two on the front I/O, and four on the rear I/O. On
the four rear I/O ports it is strongly recommended to use a cable below 3 metres in length for
USB 2.0 devices. All six ports are high-speed, full-speed, and low-speed capable.
One USB peripheral may be connected to each port. For connecting more USB devices to the
CP6003-SA than there are available ports, an external USB hub is required.
Table 2-5:
DIP Switch SW1 Function
SWITCH
FUNCTION
1
POST Code indication
2
SPI flash boot selection
3
Reserved
4
Clear uEFI BIOS settings
Table 2-6:
DIP Switch SW2 Function
SWITCH
FUNCTION
1
PCI frequency of the CompactPCI interface
2
PCI/PCI-X mode of the CompactPCI interface
Table 2-7:
DIP Switch SW3 Function
SWITCH
FUNCTION
1
PCI/PCI-X frequency multiplier configuration
2
PCI/PCI-X mode of the PMC interface
Note ...
The USB host interfaces can be used with maximum 500 mA continuous load
current as specified in the Universal Serial Bus Specification, Revision 2.0.
Short-circuit protection is provided. All the signal lines are EMI-filtered.