Kontron AT8901 User Manual Download Page 1

AT8901 USER GUIDE

AdvancedTCA

M5301_TECH_2 Manual ID

1.0 Revision Index

1 June, 2006 Date of Issue

Summary of Contents for AT8901

Page 1: ...AT8901 USER GUIDE AdvancedTCA M5301_TECH_2 Manual ID 1 0 Revision Index 1 June 2006 Date of Issue...

Page 2: ...visit our Internet web site www kontron com Disclaimer Copyright 2006 Kontron AG All rights reserved All data is for information purposes only and not guaranteed for legal purposes Information has bee...

Page 3: ...i General Instructions on Usage xii Two Year Warranty xiii Chapter 1 1 Introduction 1 2 1 1 Product Overview 1 2 1 1 1 AT8901 Features 1 3 1 1 2 General compliances 1 4 1 1 3 Board Layout 1 5 1 1 4 Op...

Page 4: ...3 7 Power Supply 3 14 3 7 1 Power Connector 3 14 3 7 2 Power Distribution 3 15 3 7 3 Power Supply AMCs 3 16 3 7 4 Power Supply RTM 3 16 3 7 5 Power Transients 3 16 3 7 6 Optional Chassis to Logic Gro...

Page 5: ...elf Test 4 8 4 4 IPMI Firmware 4 10 4 4 1 Sensor Data Record SDR 4 11 4 4 2 Field Replaceable Unit FRU Information 4 14 4 4 3 E Keying 4 14 4 4 4 IPMC Firmware Code 4 14 4 4 5 LEDs 4 15 4 4 6 Hot Swap...

Page 6: ...e Port Mapping 3 6 3 7 Base Uplink J27 Pin Assignment 3 7 3 8 Base Uplink J27 LEDs Signification 3 7 3 9 AMC Bay Address 3 9 3 10 AMC B1 Channel Assignment 3 9 3 11 AMC B2 Channel Assignment 3 10 3 12...

Page 7: ...List of Figures 1 1 AT8901 Board 1 5 3 1 Functional Block Diagram Base Board 3 2 3 2 Block Diagram AMC GbE Cross connect via update channels 3 8 3 3 Front Panel of AT8901 3 18 3 4 Symbols Chart 3 19 3...

Page 8: ...Kontron AG reserves the right to change modify or improve this document or the product de scribed herein as seen fit by Kontron AG without further notice Trademarks Kontron AG and the Kontron logo ar...

Page 9: ...title warn of hazards due to electrical shocks 60V when touching products or parts of them Failure to observe the precautions indi cated and or prescribed by the law may endanger your life health and...

Page 10: ...ct contains batteries for RTC or memory back up ensure that the board is not placed on conductive surfaces including anti static plas tics or sponges They can cause short circuits and damage the batte...

Page 11: ...tal requirements This applies also to the operational temperature range of the specific board version which must not be exceeded If batteries are present their temperature restrictions must be taken i...

Page 12: ...inal cost of purchase if appropriate In the event of repair re funding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron AG and the remaining part of the ori...

Page 13: ...AT8901 Introduction Page 1 1 AT8901 User Guide Introduction Chapter 1...

Page 14: ...provides 2 AMC slots for customization This unique versatile design allows cost optimised tailoring to the requirements of the application The Base Interface switch provides Gigabit Ethernet services...

Page 15: ...lities Full Redundancy support Base Interface PICMG 3 0 Non blocking layer 2 3 switching routing 4x10 100 1000BASE T uplinks on front panel 2xGbE connection to AMC slot B1 1xGbE connection to AMC slot...

Page 16: ...ARP 1 1 2 General compliances The AT8901 conforms to the following specifications PICMG 3 0 AdvancedTCA Base Specification Revision 2 0 AMC 0 AMC Base Specification AMC 2 AMC Gigabit Ethernet 10 Gigab...

Page 17: ...16 R17 R24 R23 R1296 C904 R10 R379 R1300 Q28 R511 R518 R517 R519 U137 C865 C912 U110 U119 U147 R1356 C867 C864 U117 U118 U114 F2 U128 R1368 C746 C975 R1433 R1436 J14 U138 C919 C55 L13 R1425 R1422 C16...

Page 18: ...visit our web site at www kontron com 1 1 5 Hot Swap Capability The board supports Full Hot Swap capability as required by PICMG 3 0 R1 0 It can be re moved from or installed in the system while it is...

Page 19: ...SDRAM interface 40 bit interface serves 32 bits of data plus 8 check bits for ECC applications 4KB on chip memory OCM DMA support for external peripherals internal UART and memory Scatter gather chai...

Page 20: ...ing IEEE 1149 1 JTAG boundary scan Broadcom 5466R PHY Advanced power management Line side and MAC side loopback Ethernet WireSpeed Cable plant diagnostics that detects cable plant impairments Automati...

Page 21: ...to 131 F Non operating 40 C to 70 C 40 F to 158 F Humidity Designed to meet or exceed the following Bellcore GR63 Section 4 1 Operating 15 90 non condensing at 55 C 131 F Non Operating 5 95 non conde...

Page 22: ...LEDs ATCA LEDs 4 LEDs Ready for Hot Swap Out of Service Healthy Heart Beat Ethernet Shielded RJ 45 connectors with integrated LED s Base Ports 4x Shielded RJ 45 connectors with integrated LED s User...

Page 23: ...rithms supported IEEE 802 1D IEEE 802 1w Quality Of Service on all ports IEEE 802 1p Full Duplex operation and flow control on all ports IEEE 802 3x Static MAC filtering Port Authentication IEEE 802 1...

Page 24: ...d MIBS Switching Package MIBs RFC 1213 MIB II RFC 1493 Bridge MIB RFC 1643 Ethernet like MIB RFC 2233 The Interfaces Group MIB using SMI v2 RFC 2618 RADIUS Authentication Client MIB RFC 2620 RADIUS Ac...

Page 25: ...2 POST multi image support loadable bootimage via network bootp tftp reliable field upgradable H W protected KCS interface to IPMC serial console support Operating System MontaVista Linux Professional...

Page 26: ...Installation Chapter 2 Page 2 1 AT8901 User Guide AT8901 Installation...

Page 27: ...you intend to install please check your specific board and or system documentation to make sure that your system is provided with an appropriate free slot in which to insert the board ESD Equipment T...

Page 28: ...he AT8901 perform the following 1 Carefully insert the board into the slot designated by the application requirements for the board until it makes contact with the backplane connectors 2 Using the eje...

Page 29: ...as the AMC is fully inserted It will turn OFF at the end of the hot swap sequence 2 5 Software Installation The AT8901 comes as a pre installed system with all necessary OS Filesystem drivers and appl...

Page 30: ...ity 1 stop bit 8N1 no flow control 2 Ensure that the board is powered up 3 Wait for boot process to complete i e until the console selection menu appears b connect Base Fabric console r reset system 4...

Page 31: ...ration may take a few minutes Management interfaces will not be available during this time Are you sure you want to save y n y Configuration Saved Base Fabric To access the CLI via Fast Ethernet manag...

Page 32: ...Hardware Description Chapter 3 Page 3 1 AT8901 User Guide AT8901 Hardware Description...

Page 33: ...IPMB A B Power Supply Unit Control Sensor IPMB AMC B1 AMC B2 AMC 2 Type 8E2S2 or AMC 2 Type 8E2F2 IPMB AMC B2 GE AMC B1 2x4 RJ45 Array BASE Interface 4 x 10 100 1000BaseT RJ45 RS232 RJ45 FE SATA FC 8...

Page 34: ...llowing way Table 3 1 PCI Slots Fast Ethernet Management Interface The internal Fast Ethernet MAC of the PowerPC 405 GPr is used as a management interface Additionally a Fast Ethernet PHY transceiver...

Page 35: ...em ory space The sector width is 64 Kbyte The Flashes are connected to the 32 bit peripheral data bus The PowerPC 405 GPr accesses the Flashes with CS0 The sector containing the bootloader code is wri...

Page 36: ...emale to SubD female adapter if required The adapter is described in the following table Table 3 5 Serial console terminal cable interface RJ45 Female to DB9 Female Signal Pin RTS 1 DTR 2 TXD 3 GND 4...

Page 37: ...e board can operate in a dual star and full mesh configuration The switch is connected to the backplane via four 10 100 1000BASE T quad PHYs and eight 10 100 1000BASE T dual magnetics The pin assignme...

Page 38: ...000BASE T dual magnetics GbE channels 0 1 to 0 4 of the switch map to uplink channels 1 to 4 The upper four RJ45 connectors on the front panel are not used for the AT8901 Table 3 7 Base Uplink J27 Pin...

Page 39: ...e channel buffered by a cross point switch The update channel connects to the base switch of the redundant Hub Board In applications with a PrAMC used as a system controller in the ATCA Hub Board the...

Page 40: ...management power AMC AMC Bay ID GA 2 0 IPMB L Address 1 B1 UGU 7Ah 2 B2 UUG 7Ch Table 3 10 AMC B1 Channel Assignment Channel Region Connection 0 GbE Local Base Switch 0 21 1 GbE Remote Base Switch 0...

Page 41: ...n 0 GbE Local Base Switch 0 23 1 GbE 2 SATA FC AMC B1 channel 2 3 SATA FC RTM STOR1 4 Fabric 5 Fabric 6 Fabric 7 Fabric 8 Fabric 9 Fabric 10 Fabric 11 Fabric 12 13 Extended 14 Extended 15 Extended 16...

Page 42: ...anagement Interface IPMI Specification 1 5 The hardware management system provides the ability to manage the power cooling and interconnect needs of intelligent devices to monitor events and to log ev...

Page 43: ...S protocol An additional LPC IF is connected to the Fabric mezzanine The CPLD controls the LEDs for the whole board via shift registers It handles the signals to monitor the AMCs fabric mezzanine modu...

Page 44: ...from each AMC Slot is implemented STOR0 and STOR1 Also an I2C IPMI connection is implemeted for an intelligent RTM The Zone 3 connector has the following pin assignment Active Low Signal Table 3 12 J3...

Page 45: ...J31 Pin Assignment PIN ROW A ROW B ROW C ROW D ROW E ROW F ROW G ROW H 1 N C N C N C N C N C N C N C N C 2 N C N C N C N C N C N C N C N C 3 N C N C N C N C N C N C N C N C 4 N C N C N C N C N C N C N...

Page 46: ...erter allows a maximum of 14A output current Two different management voltages 3 3V and 5V and five payload voltages 3 3V 2 5V 1 8V 1 25V and 1 2V are generated by point of load converters These are e...

Page 47: ...e refer the AMC Specification 3 7 4 Power Supply RTM The RTM has its own power supply The 12V payload power is generated by a hot swap con troller and for the management power a current limit switch i...

Page 48: ...et on the CPU when pressed for less than 1 second and a complete board reset including IPMI when pressed for more than 2 seconds 3 9 Jumpers Five jumpers in the upper right corner allow debug settings...

Page 49: ...ion Page 3 18 AT8901 User Guide 3 10 Display Elements Figure 3 3 Front Panel of AT8901 Serial Port Reset Switch Ethernet Management LED Toggle Not Used ATCA LEDs Base Uplink Fabric Uplink Not Used Bac...

Page 50: ...Hot Swap ATCA BLUE LED Serial Port Ethernet Table 3 17 ATCA LEDs Signification LED Signification ATCA LED3 HB yellow User definable ATCA LED2 HY green On Healthy PPC IPMC Blink Sensor out of range ATC...

Page 51: ...Ds for status indication for the base interfaces User LED1 displays infor mation on the status of the base switch Each RJ45 displays the status of the link with the two integrated LEDs The reset switc...

Page 52: ...ment Table 3 19 Switch LED Assignment Switch LED Number Base Interface Logical ATCA Slot 1 SMCA B Ch 1 ShMC s 2 Ch 2 other Hub 3 Ch 3 3 4 Ch 4 4 5 Ch 5 5 6 Ch 6 6 7 Ch 7 7 8 Ch 8 8 9 Ch 9 9 10 Ch 10 1...

Page 53: ...Software Description Page 4 1 AT8901 User Guide AT8901 Software Description Chapter 4...

Page 54: ...information of system configuration using CLI commands refer to documentation AT8901 2 3 CLI Reference Manual 4 1 Supported RFCs The Software supports the following standards and RFCs 4 1 1 Managemen...

Page 55: ...r 2002 RFC 3416 Version 2 of SNMP Protocol Operations December 2002 RFC 3417 Transport Mappings December 2002 RFC 3418 Management Information Base MIB for the Simple Network Management Protocol SNMP D...

Page 56: ...P Dynamic L2 Multicast Registration IEEE 802 1Q Virtual LANs with Port Based VLANs IEEE 802 1v Protocol based VLANs IEEE 802 1p Ethernet Priority with User Provisioning Mapping IEEE 802 1X Port Authen...

Page 57: ...Encoding Long Option in the Dynamic Host Configuration Protocol DHCPv4 RFC 3580 802 1X RADIUS Usage Guidelines Draft ietf magma snoop 11 txt Considerations for IGMP and MLD Snooping Switches 4 1 3 Ro...

Page 58: ...uting 4 1 4 QoS Bandwidth Policing Min and Max per port per VLAN Committed Information Rate CIR Maximum Burst Rate MBR Per Port Interface Per VLAN Filtering L3 L4 Access Lists IP Classification 6 Tupl...

Page 59: ...twork Addresses IANA ifType MIB IEEE 802 1X MIB IEEE8021 PAE MIB IEEE 802 3AD MIB IEEE8021 AD MIB 4 2 3 Routing Package MIBs Draft ietf ipv6 rfc2096 update 07 txt IP Forwarding Table MIB IANA Address...

Page 60: ...3 1 2 Boot Steps In addition to the Power On Self Tests described above the bootloader logs the board startup sequence in the postcode low byte register A postcode value is written each time a step i...

Page 61: ...C 0x09 Init I2C PC_INITRAM 0x0A Init SDRAM controller and SDRAM PC_TESTRAM 0x0B Test SDRAM PC_INITSEQ 0x0F Board init sequence completed PC_INITBOARD 0x10 Board init ok stack set up ok board info stru...

Page 62: ...ible the IPMC activates the redundant IPMB bus to re establish system management communication to report the fault The onboard DC voltage current and temperature sensors are monitored by the IPMC micr...

Page 63: ...queried using Device SDR commands Base Board sensors that have been implemented are listed below Table 4 3 AT8901 sensors IPMI Sensor Name Unit Scanning Enabled Under Power State Health LED Sensor Ipm...

Page 64: ...nge 48V A RTN FUSE discrete On Off No change 48V B RTN FUSE discrete On Off No change CPU Status discrete On No change Post Code discrete On No change Power FRU1 Watts On No change Power FRU2 Watts On...

Page 65: ...sent to signal the failure of a bus or conversely the recovery of a bus 4 4 1 2 FRU Hot Swap The hot swap event message conveys the current state of the FRU the previous state and a cause of the state...

Page 66: ...ection 3 7 2 3 of the PICMG 3 0 specification When the board enters M3 power state the shelf manager reads in the board point to point connectivity record from FRU and determines whether the board can...

Page 67: ...arrier also implements the OOS LED Short blink mode for its Advanced MC mates on detection of power denied conditions As per AMC 0 if the AMC current draw requirements exceed AMC 0 carrier power budge...

Page 68: ...nd the IPMC will move from the M4 state to the M5 state At the M5 state the IPMC will ask the ShMC for permission to move to the M6 state The Hot Swap LED will indicate this state with a short blink O...

Page 69: ...artitions labelled with F contain factory default images which are known to work properly on the AT8901 The factory default images cannot be updated using the CLI commands described below Table 4 7 FL...

Page 70: ...n be defined but only one is active at a time To display the currently available startup configurations the CLI command show is used Base Fabric show startupconfig startup ACT NR KERNEL SYSTEM APPLICA...

Page 71: ...so used to activate one of the available startup configurations The syntax is startupslot 3 activate once This command would activate the startup configuration 3 upon next system reset The optional pa...

Page 72: ...e currently active images are not overwritten 2 Select a configuration for base and fabric switch for the new software release This can be done by choosing the factory default or by storing the runnin...

Page 73: ...e available during this time Are you sure you want to save y n y Configuration Saved Base Fabric Instead of storing the configuration for both base and fabric switch base only or ext only might be giv...

Page 74: ...pdate image is corrupted the IPMC will be able to restart all the same by means of its rollback functionality The IPMI software package file is stored in the result ppc405 firm ware path of the releas...

Page 75: ...AT8901 Getting Help Page A 1 AT8901 User Guide Getting Help Appendix A...

Page 76: ...Tel 450 437 5682 Tel 49 0 8341 803 333 Fax 450 437 8053 Fax 49 0 8341 803 339 If you have any questions about Kontron our products or services visit our Web site at www kontron com You also can contac...

Page 77: ...he technician will instruct you on the return procedure if the problem cannot be solved over the telephone 4 Make sure you receive an RMA from our Technical Support before returning any mer chandise F...

Page 78: ...rs and in voice s associated with the item s in question Ensure that the unit is properly packed Pack it in a rigid cardboard box Clearly write or mark the RMA number on the outside of the package you...

Page 79: ...________________________ Province State _______________________ Country ________________________ Postal Zip Code _______________________ Phone Number ________________________ Extension _______________...

Reviews: