Page 1: ...CALL GSM Alarm System For a better understanding of this product please read this user manual thoroughly before using it S USER MANUAL Konlen Technology The proffessional home alarm system provider w...
Page 2: ...nitialization Enter Settings Exit Settings Factory Reset Coding of Remote Controller Delete Remote Controller Coding of Defense Zone Delete Defense Zone Change Password Change Operation Password Chang...
Page 3: ...SMS Notification for Arm Disarm Defense Zone Programming Home Arm Defense Zone Setting Voice Recording Siren Setting Operation Instructions System Status Remote Controller Operate Out Arm Home Arm Dis...
Page 4: ...m by SMS or call remotely SOS fire gas door hall window balcony and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wire...
Page 5: ...2 Wired terminal block Alarm Panel front schematic diagram Alarm Panel back schematic diagram Speaker PIR Siren Alarm Host Diagram Alarm Host Diagram...
Page 6: ...ired sensor 4 support both NO and NC Wired sensor 5 support both NO and NC Positive of siren red cable Negative of siren black cable Wired sensor 7 support both NO and NC Wired sensor 6 support both N...
Page 7: ...isarm status Finally turn on the backup battery switch In the state of disarm input 4 digit password by the keypad on the main unit and press button to confirm You will hear a voice prompt please ente...
Page 8: ...246 The remote controller has to be code to the alarm host in order to perform normally In setup state use keypad to input 20 input the remote controller number 1 8 and then press to confirm The main...
Page 9: ...eypad to input 23 input the defense zone number you want to code 01 99 and then input to confirm The main unit emits a long beep and the corresponding defense zone is displayed on the screen You will...
Page 10: ...leted Operating method 30 XXXX XXXX indicates the new 4 digit password For example change the system password to 1012 Operating method 30 1012 LCD display In setup status use keypad to input 31 then i...
Page 11: ...system the two digits EE of the minute the two digits FF of the second and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating method 32 AA BB CC DD EE FF...
Page 12: ...ice prompt setting completed LCD display In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear...
Page 13: ...by remote controller or SMS is immediate arm without delay In setup state input the command 45 XX XX indicates the delay time of alarm XX 01 99 1 sec to 99 sec Note The setting is effective only when...
Page 14: ...elete the third alarming user number from the system Operating method 53 LCD display In setup state input 57 59 then input the SMS receiving number and then press button to confirm The main unit will...
Page 15: ...input 60 then the defense zone number 01 99 then input defense zone type 1 4 then input defense zone location number 1 8 and then select siren on off 0 1 at last press to confirm You will hear the ma...
Page 16: ...nfirm The main unit will make a long beep and a voice prompt setting completed Operating method 61 XX A XX indicates 01 99 is defense zone 1 to defense zone 99 A indicates 0 Home arm but not alarm For...
Page 17: ...sounds or not by 0 1 button and then press to confirm The main unit will emit a long beep and a voice prompt setting completed Operating method 75 A A indicates 0 Siren off 1 Siren on System default 0...
Page 18: ...means for the safety while somebody is at home you need to enable the peripheral door window balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors which...
Page 19: ...The SMS command is Remote Control Password Default 1234 1 After the setting the host makes a Di sound ARM LED is on and you will receive a SMS System armed LCD display You can also set disarm by SMS r...
Page 20: ...h preset number for 3 times circularly Press Read the alarm information Press 1 Main unit stops alarming and Arm it stops calling users Press 2 Main unit stops alarming and Disarm it stops calling use...
Page 21: ...you can use the main unit to make any call just like a land line telephone Dial telephone number on keypad press button the main unit will make a beep and the Signal indicator will be flashing After t...
Page 22: ...ng the main unit you should check the signal of the installing place in order to ensure the unit can perform well In setup state input 81 the main unit will make a long beep and display 00 XX XX indic...
Page 23: ...ective effective effective effective effective effective effective effective effective effective effective effective 8888 1234 180sec real time real time real time real time real time real time 24 hou...
Page 24: ...the alarm system in dirty locations otherwise the electronic elements will be damaged Do no place the system in excessively hot locations High temperature will shorten t he service life of electronic...
Page 25: ...nnected to a safe and reliable socket Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless...
Page 26: ...r the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send...
Page 27: ...ensors detectors are packed separately They include remote controller outdoor siren transmitter wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button baluster etc...
Page 28: ...MOBILE CALL GSM Alarm System 2011 12 V2 0...