![Konica Minolta SONIMAGE HS2 Operation Manual Download Page 203](http://html1.mh-extra.com/html/konica-minolta/sonimage-hs2/sonimage-hs2_operation-manual_1994056203.webp)
5 .6 Common Functions
203
Chapter 5
5 .6 .2 Direct Touch and Drag
By dragging a certain area in an ultrasound image, a parameter assigned to the area can be changed . For details
about assigning functions, refer to "Direct Touch Screen" in the "Operation Manual: Applications" .
The name of a manipulable parameter is displayed at the center of each area .
With a touch of a direct touch area, the name of the assigned function appears at the center of the (direct touch)
area .
• Drag left / right:
Drag right / left to increase / decrease a parameter .
• Drag up / down:
Drag up / down to increase / decrease a parameter .
z
B-mode/ Elastography-mode
<Single display>
(3)
(1)
(2)
No .
Location
Direction
Remarks
(1)
B-image Area Left Side
*
Up/Down
The assigned functions can be changed by customizing the settings .
You can also not assign any functions .
D Angle Correction and Gate Size operations are not available in Elastogra-
phy-mode .
(2)
B-image Area Right
Side
*
Up/Down
The assigned functions can be changed by customizing the settings .
You can also not assign any functions .
D Angle Correction, Gate Size, and Ana-M Angle operations are not avail-
able in Elastography-mode .
(3)
B-image Area Bottom
Side
Left/Right
You can also not assign any functions by customizing the settings .
B Gain when the image is in a live state .
Gain operations are not available in a frozen state .
*
: In 2B-mode, the side with vertical scale is the left side and the opposite side is the right side .
Summary of Contents for SONIMAGE HS2
Page 1: ...EN 01...
Page 2: ......
Page 6: ...6...
Page 7: ...7 Introduction...
Page 41: ...41 For all product inquiries contact your service representative Support...
Page 42: ...42...
Page 43: ...43 Chapter 1 Product Overview...
Page 68: ...68...
Page 69: ...69 Chapter 2 Before Examination...
Page 84: ...84...
Page 85: ...85 Chapter 3 Starting Examination...
Page 122: ...122...
Page 123: ...123 Chapter 4 Diagnosis Mode...
Page 181: ...181 Chapter 5 Common Function in Ultrasound Images...
Page 219: ...219 Chapter 6 Reviewing Printing and Transferring Images...
Page 232: ...232...
Page 233: ...233 Chapter 7 Maintenance Inspection...
Page 243: ...243 Chapter 8 Transducer and Biopsy...
Page 270: ...270...
Page 271: ...271 Chapter 9 MI TI...
Page 283: ...283 Chapter 10 Acoustic Output...
Page 286: ...286...
Page 287: ...287 Chapter 11 Others...
Page 305: ...305...
Page 306: ...306...
Page 307: ......