5.2 Dealing with plate jams
58
3
Load the plate into the cassette, and
perform the image erase process .
REFERENCE
•
Loading the plate
Refer to “4 .1 .3 Loading the Plate into the Cassette”(p .
40)
•
Erasing images
Refer to “3 .2 Image Erase Operation”(p . 30)
5 .2 .4
If the Plate’s Back End
is Visible From the Top
Door’s Opening
1
Open the left door .
2
While rotating the dial to the right, pull out
the plate from the top door’s opening .
IMPORTANT
•
Make sure the plate does not hit or rub against the top
door or any other component .
•
Continue to turn the dial until the plate is completely
out of the device .
Dial
3
Hold the lever up, and remove the cas-
sette .
Lever