9. Remote panel utility (Only for magicolor 1600W)
Field Service
V
er. 1.0 Nov. 200
8
54
magicolor 1600W magicolor 1650EN
Adjustment / Setting
9.2.2
Set Default
9.2.3
Calibration
9.3
User Service tab
9.3.1
Top Adjustment
Display
Content
Apply
• Toner Low Message:
Specifies whether a printer indicator blinks or a warning message
appears in the status display box of the Remote Panel Utility when
toner is about to run out. If Off is selected, neither of these notifications
appear when the toner is about to run out.
The default setting is On.
“On” / Off
• Toner Out Stop:
Specifies whether to stop or continue printing when a toner empty con-
dition is detected.
The default setting is On.
“On” / Off
• Energy Save Time:
Specifies the length of time before the machine enters energy saver
mode after the last print is received or the last key operated.
The default setting is 30 (min).
5 / 15 / “30” / 60
• Auto Continue:
If Off is selected, the next print job will not be performed if a paper size
error occurred in the printer, unless the Clear key is pressed to cancel
the error.
If On is selected, the next print job is sent if a paper size error occurred
in the printer, the error is automatically cancelled, and the next print job
is performed.
The default setting is Off.
On / “Off”
Display
Content
Start
Performs the calibration operation.
Function
• Adjusts the top margin of media for single-sided printing.
Use
• To correct a misaligned print image.
Plain Paper:
Adjust the head margin of plain paper.
Thick Paper:
Adjust the head margin of thick paper.
Envelope:
Adjust the head margin of envelope.
Setting
/procedure
-15 to +15 (1 step: 0.2 mm)
Summary of Contents for magicolor 1600W
Page 3: ...ii Blank Page...
Page 28: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Main body magicolor 1600W magicolor 1650EN...
Page 174: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Lower Feeder Unit...
Page 179: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Lower Feeder Unit General Blank Page...
Page 193: ...4 Jam display Field Service Ver 1 0 Nov 2008 16 Lower Feeder Unit Troubleshooting Blank Page...
Page 194: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Duplex Option...
Page 199: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Duplex Option General Blank Page...
Page 209: ...3 Other Field Service Ver 1 0 Nov 2008 12 Duplex Option Maintenance Blank Page...