Calibration
105
Choosing a Calibration Mode
The IC-301 print controller provides you with two calibration
modes:
•
Off-the-glass:
Uses the scanner platen to perform off-the-glass
calibration
•
Densitometer: Uses the
DTP34 densitometer, which is a “high
speed”color measurement instrument, to report densitometer
and dot data
You select the calibration mode in the Preferences window, see
Calibration Process
This section describes the off-the glass calibration process. If you
want to use the DTP34 densitometer to calibrate, refer to the
X-Rite
DTP34 Densitometer Operator’s Manual
and follow the IC-301
print controller calibration wizard
Table 10: Fixed density values for coated paper
Toner
Density value
Cyan
1.6
Magenta
1.66
Yellow
1.054
Black
1.8
Note:
It is recommended that:
1.
After you perform the first calibration, you print the
IQ_Test_(TAB/A3).pdf
file from the
D:\Sample_Files\(USA/Europe)\IQ Files
folder. Each time
you calibrate, use this file as a visual reference to verify that the printer has
returned to its start point.
2.
You calibrate both the printer and scanner at the same time. If you only
place the print chart on the platen, the printer is calibrated. If you only place
the scanner chart on the platen, the scanner is calibrated.
Summary of Contents for IC-301
Page 2: ......
Page 28: ...20 Chapter 2 Getting Started...
Page 42: ...34 Chapter 3 Printing From Your Computer The IC 301 print controller Web Center appears...
Page 60: ...52 Chapter 4 Basic Workflows...
Page 90: ...82 Chapter 5 Managing Jobs...
Page 110: ...102 Chapter 6 Production Printing...
Page 111: ...Color Workflow Calibration 104 Color Tools 108...
Page 192: ...184 Appendix A Setting Parameters...
Page 210: ...202 IC 301 Print Controller User Guide Storage area 10 title bar 10 toolbar 10...
Page 211: ......
Page 212: ...www konicaminolta com Copyright 2005 KONICA MINOLTA BUSSINESS TECHNOLOGIES INC 2005 4...