76
3
En
vir
onment Set
tings/Other Set
tings
Display Type
Configure the display type for the measurement results.
Memo
All display types are selected under the initial settings.
Operating Procedure
Start the procedure from the <Measurement cond.> - <Display cond.> screen.
1
Use [
] or [
] to move the cursor to “Display type”,
and then press the [Confirmation] key.
The <Display type> screen
is displayed.
2
Use [
] or [
] to move the cursor to the desired
display type, and then press the [Confirmation] key.
Selections
Absolute value: Displays the absolute value of the
colorimetric and the gloss value.
Difference: Displays the color difference against the
target color. The measurement that failed the pass/fail
judgment based on the tolerance will be highlighted in
red.
Audi2000(ΔEc): Displays ΔEc (Audi2000), the average
value, and the maximum value.
Audi2000(ΔEp): Displays ΔEp (Audi2000), the average
value, and the maximum value.
MI: Displays the metamerism index. (If illuminant 2 has
not been set, a number will be displayed.)
Pass/Fail: Determines whether the color difference
related to the target are within the tolerance range set in
advance. If within the tolerance, the judgment will be
displayed as “Pass”. If even one difference is not within
the tolerance, the judgment will be displayed as “Fail”.
Abs. Graph: Displays a graph of the absolute value of the colorimetric value.
Diff. Graph: Displays a graph showing the color difference against the target color.
Line graph: Displays a graph of the color values according to angle differences.
Memo
A check mark means the item is selected.
3
After all settings have been configured, use [
] or [
] to move the cursor to “OK”, and then press
the [Confirmation] key.
The selection is confirmed and the screen returns to the previous screen.
Notes
If [ESC] is pressed without pressing the [Confirmation] key, the settings will not be changed and the screen
will return to the <Display cond.> screen.
Sample
Measurement cond.
Display cond.
Display type
Equation
CMC
Direction
Double-Path
Color space
L*C*h
Sample
Measurement cond.
Display cond.
Display type
Equation
CMC
Color space
L*C*h
Display type
OK
Cancel
Absolute value
Difference
MI
Pass/Fail
Audi2000 (∆Ec)
Audi2000 (∆Ep)
Abs. Graph
Diff. Graph
Line graph
Summary of Contents for CM-M6
Page 1: ...Instruction Manual Please read before using the instrument...
Page 18: ...15 Names and Functions of Parts 1 8 9 4 6 5 2 3 10 11 12 14 13 7...
Page 102: ...99...
Page 119: ...116 5 Troubleshooting Chapter 5 Troubleshooting Message List 117 Troubleshooting 119...
Page 123: ...120 6 Appendix Chapter 6 Appendix Main Specifications 121 Dimensions 122...
Page 125: ...122 6 Appendix Dimensions Unit mm 50 M6 1 0 DEPTH 6 M6 1 0 DEPTH 6 55 33 152 3 49 5 81 239...
Page 126: ...123...
Page 128: ...En 9222 A9DT 13 2016 KONICA MINOLTA INC BIFCGK...