DRAFT
10. SER
V
ICE MODE
Field Service
V
er. 1.0 Feb. 2010
130
ADJUSTMENT
/
SETTING
10.6.2
Scan Adjust Value
A. Use
• Adjusts magnification in the main scan direction.
• Use when replacing the PH unit.
• This adjustment is necessary when the adjustment values are cleared due to the
replacement of the EEPROM on the print control board or other reasons.
B. Procedure
1.
Touch [Main Scan Adjust]
→
[Main Scan Page] to print the test pattern.
2.
Make adjustments so that the gray area on each color sample of the output test pattern
becomes parallel to the main scan direction.
Calculate the correction values for cyan, magenta, and yellow in the following way.
<1> Check the numbers indicated on the ends of A and B which correspond to the darkest
black lines in the gray area of each color pattern.
(In the example of the yellow pattern, “1” is selected for the end of A and “7” is selected
for the end of B.)
<2> The number indicated on the end of A minus the number on the end of B equals the
correction value.
(In the example of the yellow pattern, the calculation is 1-7=-6. “-6” is the correction
value.)
A121F3C504DA
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
A
B
Summary of Contents for bizhub C35
Page 1: ...DRAFT SERVICE MANUAL 2010 02 2010 02 Ver 1 0 Ver 1 0 FIELD SERVICE ...
Page 3: ...DRAFT ii Blank Page ...
Page 28: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Main body ...
Page 227: ...DRAFT 11 FAX PROTOCOLS Field Service Ver 1 0 Feb 2010 188 ADJUSTMENT SETTING Blank Page ...
Page 301: ...DRAFT 17 IC protector Field Service Ver 1 0 Feb 2010 262 Blank Page ...
Page 314: ...DRAFT SERVICE MANUAL 2010 02 Ver 1 0 FIELD SERVICE Lower Feeder Unit PF P08 ...
Page 317: ...DRAFT Lower Feeder Unit OUTLINE MAINTENANCE Field Service Ver 1 0 Feb 2010 ii Blank Page ...