To change the timing of media-break detection
6
6.6
6.6
To change the timing of media-break detection
When the winding diameter of the media falls below the detection range of the remaining media sensor, the
media conveyance stops.
If conveyance stops even though sufficient media remains or conveyance does not stop even when the re-
maining media becomes insufficient, the problem may be solved by adjusting the remaining media sensor.
The detection range shall be set between the remaining media sensor and unwinder spindle. When you widen
this interval, the detection timing becomes earlier. When you reduce this interval, the detection timing be-
comes later.
1
Loosen the rotation knob of the remaining media sensor.
2
Adjust the position by measuring the interval between the remaining media sensor and unwinder spin-
dle.
3
After determining the position, securely tighten the rotation knob to fix the remaining media sensor.
NOTICE
%
Normally, configure the default setting, 9 mm.
%
When changing it, it is recommended to adjust it by the millimeter. You shall be responsible for
changes in the setting.
Unwinder spindle
Recommended
detection range
Remaining media sensor
Rotation knob
9 mm
Summary of Contents for AccurioLabel 230
Page 1: ...AccurioLabel 230 QUICK GUIDE...
Page 2: ......
Page 7: ...1 Introduction...
Page 8: ......
Page 12: ...1 6 AccurioLabel 230 Configuration and usage of this manual 1 1 5...
Page 13: ...2 Before using this machine...
Page 14: ......
Page 35: ...3 Printing workflow...
Page 36: ......
Page 68: ...3 34 AccurioLabel 230 Operation after printing 3 3 3...
Page 69: ...4 Handling paper...
Page 70: ......
Page 125: ...5 Cleaning...
Page 126: ......
Page 151: ...6 Troubleshooting...
Page 152: ......
Page 179: ...7 Appendix...
Page 180: ......
Page 194: ...7 16 AccurioLabel 230 Typical specifications 7 7 2...