Chapter 6 Adjustment
6-8
10
Confirm the step in the justifier guide 2 while the cassette is fixed with the justifier guide.
If the left edge of the justifier guide 1 is between the position of the A and B of the justifier guide 2, it is
within the specification, and there is not need for adjustment of the current
justifier
.
Go to Step 13 if you do not need to change the Amount of Justification.
11
Change the justifier value if the step is not within
specification, and reconfirm.
1. Click the [Move To HP] button.
2. Change the amount of justification.
3. Click the [Position of Justification] button.
4. Confirm the step of the justifier guide 2 again.
Repeat until the step come within the specified value.
Measurement
Step between the justifier guide 2
and the justifier guide 1 when the
standard cassette is fixed by
justifier mechanism
Specified
value
2 ± 0.3 mm
2.3mm
1.7mm
2.0mm
Justifier Guide 2
A
B
Justifier Guide 1