270
406388/F
Note
Learn parameter 1; Pulse Length and Learn Parameter 2; TVG. Ping interval:
60. The PX TrawlEye will start with pulse length 64µs and TVG 20 and use this
setting for 60 pings, then the TrawlEye will keep 64µs, but change TVG to 30 for
the next 60 pings, then 64µs and TVG 35 for 60 pings and then 64µs and TVG40
for 60 pings. The TrawlEye will then change pulse length to 128µs and TVG to 20
and run through all TVGs with this pulse length. After 2048µs and TVG 40 has
been pinging 60 times the TrawlEye will start over with 64µs and TVG 20 and run
through all settings again and again until you take it up and configure the sensor to
the preferred settings you found during the Learn mode
Ping Interval
The
Ping Interval
function permits you to choose the time (in milliseconds)
between each transmission ("ping"). Specify the interval between each ping.
Relevant topics
•
Common configuration parameters, page 271
•
Non editable information about the sensor, page 274
Related topics
Configuring a PX TrawlEye sensor, page 143
Creating a TrawlEye view, page 201
Creating a true motion (echogram) TrawlEye view, page 102
Overview of sensors channels and frequencies, page 309
Overview of catch monitoring measurements, page 312