442704/A
649
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 10 VA (Approximately)
The power supply is connected to a dedicated socket on the rear side of the Processor Unit.
Related topics
Power requirements, page 648
Technical specifications, page 643
Operating Panel power requirements (Mk2)
•
Make and model
: ST90 Operating Panel Mk2
•
Voltage requirement
: 115/230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 10 W (Approximately)
Related topics
Power requirements, page 648
Technical specifications, page 643
Operating Panel power requirements (Mk3)
•
Make and model
: ST90 Operating Panel Mk3
•
Voltage requirement
: Not applicable
This unit is powered by means of the USB connection.
Related topics
Power requirements, page 648
Technical specifications, page 643
Transceiver Unit power requirements
•
Make and model
: ST90 Transceiver Unit
•
Voltage requirement
: 230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15 %
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...