188
442704/A
Lowering and hoisting the transducer using the Hoist/Lower
Switch
The Operating Panel controls the lowering and hoisting of the transducer. Dedicated buttons
are provided for the physical transducer locations. You can also do this from the Motor
Control Unit. Local control is useful for maintenance purposes.
Prerequisites
You need a suitable screwdriver
or a large coin to open the Motor
Control Unit cabinet. 3-phase
voltage for the hoisting motor
and +24 VDC from the internal
power supply are available. Both
indicator LEDs inside the Motor
Control Unit are lit.
Context
Use
Hoist/Lower Switch
(S302)
in the upper part of the cabinet
to control lowering and hoisting.
For normal operation from the
Operating Panel, the switch must
be set to
REMOTE
.
Procedure
1
Make sure that you have
sufficient water depth below
the keel before you lower
the transducer.
If your vessel is in dry dock, make sure that you have sufficient height between the hull
and the dry dock floor. The space under the hull must be free from tools, scaffolding,
personnel and other obstacles.
2
Open the cabinet door.
WARNING
High voltages are used. This equipment must be serviced only by qualified
personnel familiar with high-voltage equipment and the potential hazards
involved. Failure to observe this precaution could result in bodily injury. You
may be exposed to electric shock. Read and understand the applicable first aid
instructions related to electric shock.
Simrad ST90 Reference Manual
Summary of Contents for Simrad ST90
Page 1: ...kongsberg com simrad Simrad ST90 REFERENCE MANUAL ...
Page 2: ......
Page 337: ...442704 A 335 Related topics Sonar views page 326 User interface ...
Page 413: ...442704 A 411 Related topics Menu system page 375 Display menu page 384 Menu system ...
Page 631: ...442704 A 629 Related topics Concept descriptions page 626 Concept descriptions ...
Page 687: ......
Page 688: ... 2021 Kongsberg Maritime ISBN 978 82 8066 211 8 ...
Page 689: ......
Page 690: ...Reference Manual Simrad ST90 ...