106
381298/C
Installing the transducer into the mounting house
When all the preparations have been made, the SN90 transducer must be installed into
the mounting house.
Prerequisites
(CD010205_100_002)
In order to do this task, the following
prerequisites must be met.
• All relevant work instructions,
procedures and standards must be
available.
• The mounting house (or a similar
construction) has been installed.
• If relevant, a suitable sealing plate
is mounted with all installation
work finalized.
• If relevant, the steel conduit is
mounted with all installation work
finalized.
• The transducer cables are
installed. A service loop is
provided immediately over the
transducer.
• All relevant drawings have been approved by the classification society.
• All relevant personnel (skilled shipyard workers, ship electricians) and their tools
must be available.
You must be equipped with a standard set of tools. This tool set must comprise the
normal tools for mechanical tasks, such as different screwdriver types, pliers, adjustable
spanners and wrenches. Each tool must be provided in various sizes. We recommend
that all tools are demagnetized to protect your equipment. The following specific tools
and items are required for this task:
• Torque wrench
• Loctite 270 (permanent high-strength threadlocker)