90
476671/B
MF94 Installation example (off keel/with blister)
The illustration demonstrates the mounting principles for a standard trunk.
Note
The drawing is not to scale.
A
As short a possible
B
795 mm (Maximum)
C
1200 mm (Minimum)
D
40 mm (Approximately)
E
Strengthening knee plates
(stiffereners)
F
Streamlined blister
G
610 mm (Approximately)
H
1200 mm (Approximately)
I
Deflection brackets must only
be welded to the shell-plating.
Thickness: 6 mm (Minimum)
The streamlined blister is an option.
The blister may work well on smaller
vessels. This is because it allows you to bring the installation trunk and hull unit down
closer to the keel. A lower position will increase the depth of the transducer relative to the
hull. The circular opening in the blister must have the same diameter as the inside diameter
of the installation trunk.
Important
The installation trunk must be secured to the bulkheads and/or the hull by means of
strengthening plates (stiffereners). The dimensions and strength of the plates must be
adequate to prevent any vibrations. This is an invariable requirement to ensure the safety of
the MF90 system and the vessel.
The shape and locations of the strengthening plates must be determined by the installation
shipyard based on the physical properties of the installation trunk, the hull and the space
available. Minimum four strengthening plates must be used. Each strengthening plate must
extend all the way from the bottom to the top of the installation trunk. Only leave a small
gap to allow access to the bolts and nuts used to secure the mounting flange. The minimum
plate thickness is 10 mm, but the classification society can specify other dimensions.
Simrad MF90 Installation Manual
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...