Prerequisites for cable installation
Correct wiring is crucial for the operational performance of the MF90 system. Electrical
connections can only be made by skilled personnel (ship electricians, technicians or
engineers). The installation shipyard must prepare detailed drawings of the electrical
system, and identify each cable.
You must be equipped with a standard set of tools. This tool set must comprise the normal
tools for cable installation tasks. This includes different screwdriver types, pliers, spanners,
a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We
recommend that all tools are demagnetized to protect your equipment. Depending on the
tasks at hand, additional tools may be required.
Refer to the cable plans and the list of cables. Detailed information about cable
specifications, termination and connectors are provided in the relevant cable drawings.
Unless otherwise specified, all cables are supplied with the MF90 delivery. In order to
ease the access for maintenance purposes, and to allow for vibration, make sure that some
slack is provided for each cable.
Note
All electric installations and corresponding wiring must be in accordance with the vessel's
national registry and corresponding maritime authority and/or classification society.
Only skilled and authorized personnel can install the MF90 cables.
Kongsberg Maritime will not accept any responsibility for errors, malfunctions or damage
to system or personnel caused by improper wiring.
Related topics
Cable layout and interconnections, page 143
Cable plans, page 145
Installing the MF90 cables, page 154
Cable drawings and specifications, page 164
Installing the topside cables
The topside/bridge cables include those used to connect the Processor Unit and the display
to each other, as well as cables for AC mains power and external devices. A high capacity
Ethernet cable connects the Processor Unit to the Transceiver Unit.
Procedure
1
Connect the power cables, but do not apply AC mains to any of the system units.
a
Connect the power cable from the uninterruptible power supply (UPS) to the
AC power outlet.
Summary of Contents for Simrad MF90
Page 1: ...kongsberg com simrad Simrad MF90 INSTALLATION MANUAL...
Page 2: ......
Page 21: ...476671 B 19 Related topics Simrad MF90 page 13 Simrad MF90...
Page 369: ...476671 B 367 Drawing file...
Page 372: ...370 476671 B Simrad MF90 Installation Manual...
Page 375: ...476671 B 373 Drawing file...
Page 378: ...376 476671 B Simrad MF90 Installation Manual...
Page 384: ...382 476671 B Simrad MF90 Installation Manual...
Page 387: ...476671 B 385 Drawing file...
Page 390: ...388 476671 B Simrad MF90 Installation Manual...
Page 393: ...476671 B 391 Drawing file...
Page 398: ...396 476671 B Simrad MF90 Installation Manual...
Page 421: ......
Page 422: ...2022 Kongsberg Maritime ISBN 978 82 8066 240 8...
Page 423: ......
Page 425: ......
Page 426: ...Installation Manual Simrad MF90...