Setting up the ES80 in a synchronized system, page 105
Cable layout and interconnections, page 79
Synchronization using Clear To Send (CTS) and Request To
Send (RTS) signals
In many applications, the synchronisation interface is based on an RS-232 serial port. Only
the Clear to Send (CTS) and Request to Send (RTS) connections of the RS-232 interface
are then used.
According to the standard specifications for RS-232, an output must generate a voltage level
of +5 to +15 VDC (logic "low"), and -5 to -15 VDC (logic "high") into a load of 3 to 7 kΩ.
An RS-232 receiver must present a 3 to 7 kΩ load , converting an input of +3 to +25 VDC to
logic "low", and an input of +3 to +25 VDC to logic "high". With a positive trigger pulse,
the offset voltage does not have any significance. Even small variations (flutter) over and
below 0 VDC will not trigger the interface.
A
Local connection
B
Connection on remote device
C
Female 9-pin D-Subminiature connector
D
Male 9-pin D-Subminiature connector
Note
RS-422 communication ports can not be used for
synchronization purposes. The port you wish to use must
be set to RS-232.
Related topics
Setting up the ES80 in a synchronized system, page 105
Cable layout and interconnections, page 79
Simrad ES80 Installation Manual
Summary of Contents for Simrad ES80
Page 1: ...kongsberg com simrad Simrad ES80 INSTALLATION MANUAL ...
Page 2: ......
Page 25: ...416739 A 23 Related topics Scope of supply page 21 Simrad ES80 page 11 Simrad ES80 ...
Page 278: ...276 416739 A 201575 Transducer connector assembly and wiring Simrad ES80 Installation Manual ...
Page 309: ......
Page 310: ... 2020 Kongsberg Maritime ISBN 978 82 8066 187 6 ...
Page 311: ......
Page 312: ...Installation Manual Simrad ES80 ...