4
Select the sensor you wish to configure in the
Sensor
list.
5
If you wish to use the built-in datagram priority, select
Auto
.
• With
Auto
enabled
, the priority list is used. Information is imported from the
sensor at the top of the list. If the sensor fails to provide information for more
than 20 seconds, data from the next sensor is used.
• With
Auto
disabled
, the priority list is not used. Information is imported from the
sensor at the top of the list. All other sensors are ignored.
6
If you wish to control the datagram priority manually,
do not
select
Auto
.
To change the priority for a given datagram, select it, and change its location on
the list using the arrow buttons.
7
If relevant, add a manual value for the sensor input.
8
At the bottom of the dialog box, select
Apply
to save your settings.
9
Repeat for each sensor interface that you need to set up.
10
Continue your work in the
Installation
dialog box, or select
OK
to close it.
Related topics
Interfacing peripheral equipment, page 228
Setting up a serial or LAN (Ethernet) port for annotation
input
Several different annotation types may be added to the echograms or other views.
They are displayed on the views if this annotation feature is enabled. You can add
annotations manually, or import information as datagrams using a serial or LAN
(Ethernet) communication port.
Prerequisites
This procedure assumes that:
• You have a vacant interface port on your Processor Unit.
• You are familiar with NMEA and other relevant datagram formats.
• You know how to set up the parameters for serial and local area network (LAN)
communication.
• The interface port is set up with the correct communication parameters.
Context
The
Sensor Installation
page allows your EK80 to communicate with external sensors
and systems. You must specify which communication port to use (LAN (Local Area
Network) or serial port). You can type a custom name to identify the sensor import. In
the list of valid datagram formats, select the format(s) to be accepted by the EK80.
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...