226
394149/D
can identify the files you have recorded during a specific mission or survey. You can
also define a maximum size of the files.
Tip
The data files will normally become very large. If you wish to record large amounts of
EK80 data, make sure that you have enough space on your hard disk. Unless your
Processor Unit is equipped with a very large disk, we recommend that you save the
data to an external storage device.
Set up the file and folder parameters before you start the recording. If you wish to
save your recorded data on an external hard disk, make sure that it is connected to
the Processor Unit.
If the current file size gets too big during recording, select
Split File
on the
Record RAW
button. This will close the current file, and then automatically continue recording to a
new file.
Record RAW
is located on the
Operation
menu.
Procedure
1
Open the
Operation
menu.
2
Select
Output
.
Observe that the
Output
dialog box opens. This dialog box contains a number of
pages selected from the menu on the left side.
3
In the
Output
dialog box, select
File Setup
.
4
On the
File Setup
page, define the recording parameters.
a
Define the output directory for the recorded files.
In order to change the output directory, both
Record RAW
and
Record Processed
recording must be set to
Off
. The same folder is used for both raw and
processed files.
b
Define a file name prefix.
By adding a prefix to the file names you can identify the files you have
recorded during a specific mission or survey.
c
Define the maximum amount of bytes to be contained in one data file.
Select
Maximum
for 1 GB file size.
The current size of the RAW data file is displayed during data recording. If the
current file size gets too big during recording, select
Split File
on the
Record
RAW
button.
Record RAW
is located on the
Operation
menu.
d
Specify the raw data recording parameters.
The
Range
setting defines the vertical or horizontal distance from where the
echo presentation starts to the end of the search area.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...