Dimensional survey accuracy requirements
for ADCP operations
Minimum accuracy requirements are defined for the dimensional survey. Higher
accuracy will provide better survey results.
Modest accuracy requirements apply when your EK80 system is only used to investigate
objects in the water column. When used for acoustic Doppler current profiler (ADCP)
measurements the accuracy requirements are increased.The accuracy requirements
provided have been determined from considerations on how they contribute to the total
EK80 accuracy. Any errors in these measurements should not contribute significantly to
depth or position errors in the soundings.
Note
The given accuracies are maximum values. If easily achievable, better accuracies
should be obtained.
Transducer
•
Position (x,y)
: ±0.05 m
•
Position (z)
: ±0.02 m
•
Pitch
: ±0.10°
•
Roll
: ±0.025°
•
Heading
: ±0.1°
Motion Reference Unit (MRU)
•
Position (x,y)
: ±0.05 m
•
Position (z)
: ±0.05 m
•
Pitch
: ±0.05°
•
Roll
: ±0.02°
•
Heading
: ±0.05°
Heading sensor
•
Heading
: ±0.1°
Global positioning system (GPS) (Antenna)
•
Horizontal position (x,y)
: ±0.05 m
•
Vertical position (z)
: ±0.005 m
Waterline reference mark
•
Position (z)
: ±0.005 m
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...