156
394149/D
Split beam transducer connection to an Amphenol socket
A split beam transducer is connected to terminals
A
through
J
on the circular 12-pin
Amphenol transducer socket (Type 97-12-19S). This socket is used on the General
Purpose Transceiver (GPT), and on several versions of the Wide Band Transceiver
(WBT).
The other end of the cable is permanently fixed to the
transducer.
The transducer is designed with the individual elements
organized in four separate sectors. It is very important
that the transducer is correctly installed with the sectors
positioned as shown in the illustration (seen from
above). Each sector is connected to a dedicated transceiver channel. In this context,
the phrase
transceiver channel
is used to describe one single pathway through the
transceiver. This pathway contains one transmitter, one preamplifier and the necessary
transmit/receive switching circuitry.
Note
We strongly recommend that you install the transducer cable in a steel conduit.
Depending on production date, the transducer can be delivered with two different cable
types. On older transducers the cable contains black and white conductors. On new
transducers the cable contains colour coded conductors.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...