148
394149/D
Battery power cable
A suitable cable must be provided if you wish to power the Wide Band Transceiver
(WBT) from a battery.
The power socket is mounted on the rear panel
of the transceiver. The socket fits a Conxall 4-pin
Mini-Con-X
®
shielded plug. One spare plug is
included with the EK80 delivery. You can use
this plug if you wish to operate the transceiver
from a battery. The plug can be ordered from the
manufacturer or purchased from Kongsberg Maritime. Use part number 390616.
•
Manufacturer
: Switchcraft Conxall
•
Manufacturer’s website
:
•
True manufacturer's part number
: SF6382–4SG–520
Pin configuration
Pin number
1
2
3
4
Voltage
+12 VDC
0 VDC
0 VDC
+12 VDC
Minimum cable requirements
•
Conductors
: 2 x 1.5 mm
2
•
Screen
: None
•
Voltage
: 60 V
•
Maximum outer diameter
: Not applicable
Related topics
Cable drawings and specifications, page 136
Cable layout and interconnections, page 85
K-Sync interface to generic RS-232 synchronization input
For transmission synchronization purposes, the K-Sync will interface a generic RS-232
serial line communication port using the CTS (Clear To Send) and RTS (Request To
Send) signals.
The synchronized product is connected to the IO Module inside the K-Sync
Synchronizing Unit. Each IO Module in the K-Sync Synchronizing Unit provides six
connectors and a configuration board for physical adjustments of the communication
parameters.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...