420
442700/A
Assigning functions to the rotary switches on the Operating Panel
The Mk2 Operating Panel is fitted with three rotary switches. The Mk3 Operating Panel
is fitted with two rotary switches. The switches are identified with numbers. Each switch
can be assigned a function related to range, gain, bearing or tilt. The
Operating Panel
page is used to assign functionality to the programmable buttons. This page is located in
the
Installation
dialog box.
The Mk1 Operating Panel offers separate
Gain
buttons to control the gain in the horizontal
and vertical views.
(The Mk1 Operating Panel is no longer provided with new sonars. This
information is provided for legacy reasons.)
Related topics
Controlling the gain and range settings, page 94
Defining the user-selected features on the Operating Panel, page 174
Functions and dialog boxes, page 413
Main menu; Functions and dialog boxes, page 414
Tilt function
The
Tilt
function allows you to control the vertical angle of the sonar beams.
Specifications
•
Horizontal views
: –10 to +60 degrees
•
Vertical views
: 0 to +90 degrees
•
Plane view
: –10 to +90 degrees
•
Inspection view:
–10 to +60 degrees
How to open
This function is opened from the
Main
menu.
Description
The transmitted sonar beams can be tilted electronically. The following methods can be
used to adjust this setting:
• Select either side of the button to choose a value.
Simrad CS90 Reference Manual
Summary of Contents for Simrad CS90
Page 1: ...kongsberg com simrad Simrad CS90 REFERENCE MANUAL ...
Page 2: ......
Page 627: ...442700 A 625 Related topics Concept descriptions page 622 Concept descriptions ...
Page 683: ......
Page 684: ... 2021 Kongsberg Maritime ISBN 978 82 8066 213 2 ...
Page 685: ......
Page 686: ...Reference Manual Simrad CS90 ...