484164/A
87
Setting to work summary
Once the CP200-5C transducer has been installed and connected to the transceiver, it can be
installed in the echo sounder user interface and set to work.
Prerequisites
Before you can set the CP200-5C transducer to work, the following prerequisites must be
met:
• All cable connections are made.
• All relevant personnel and tools are available.
• A compatible motion sensor is installed. ADCP operations cannot take place without
input from a motion sensor. The CP200-5C system has been designed to match the
motion reference unit (MRU) sensors manufactured by our Seatex division. Descriptions
of all available MRU types are provided on our website.
• A software license is available.
Context
Some of these tasks may be done while the vessel is in dry dock. However, we assume that
the vessel is set afloat before you start with the "setting to work" procedures.
Note
You must never turn on the echo sounder system when the ship is in dry dock. The transducer
may be damaged if it transmits in open air. It is therefore very important that the echo
sounder system remains turned off when the vessel is in dry dock, and that no one tries
to use it.
Procedure
1
Install the software license.
The settings provided by the
Software License
page allow you to type a license code
(text string) to unlock the ADCP functionality. The
Software License
page is located in
the
Installation
dialog box.
Summary of Contents for Simrad CP200-5C
Page 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Page 2: ......
Page 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Page 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Page 101: ...484164 A 99 Drawing file ...
Page 110: ... 2022 Kongsberg Maritime ...