Installation
20220752H
19
5 INSTALLATION
5.1 General
This section provides detailed information required to
successfully install an IS15 Instrument System utilising the IS15
Wind, IS15 Tack and IS15 Wind Transducer unit. It also
describes the connection to peripheral equipment and
interconnection with other types of IS15 instruments.
5.2 Instrument Head Mounting
The instrument head is fully waterproof from the front and can,
therefore, be installed on deck or below.
Caution !
Do not install the instrument where moisture at the rear could be
present. It can cause damage by entering the breathing hole or by
coming into contact with the electrical connectors.
The position selected should, in the first instance, meet the
requirements of the helmsman, or crew.
The selected surface for the instrument head must be flat and
even to within 0.5 mm.
Before installation, note the Serial Number of the unit and keep
it in a safe place.
0.5 mm max.
✓
✗
✗
Figure 5-1 - Installation
1.
Do not remove the protection film on the display before the
installation and setup is completed.