Seapath 320
32
Man_techn_seapath320/rev.1
3.2.3
Processing Unit
When installing the Processing Unit, consider the following:
•
The unit is designed for indoor installation and should not be exposed to heavy
vibrations, transformers or similar.
•
The unit should be resiliently mounted in a 19-inch rack to be in accordance with the
environmental standard IEC60945/EN60945.
•
The unit has an internal fan and requires free airflow from the rear and out to the
sides. It is recommended that ventilation or air conditioning is provided in order to
keep the ambient operating temperature 20
°
C. The best location is typically
in the instrument room or on the bridge mounted into a 19-inch rack with good
ventilation and resilient mounting.
•
It is recommended that the area around the unit is kept free from dust and static
electricity.
•
All connections to the unit are on the rear side and available space for cable
connections and service must be provided.
3.2.4
HMI Unit
When installing the HMI Unit, consider the following:
•
The unit is designed for indoor installation and should not be exposed to heavy
vibrations, transformers or similar.
•
The unit should be resiliently mounted in a 19-inch rack to be in accordance with the
environmental standard IEC60945/EN60945.
•
The unit has an internal fan and requires free airflow from the rear and out to the
sides. It is recommended that ventilation or air conditioning is provided in order to
keep the ambient operating temperature 20
°
C. The best location is typically
on the bridge mounted into a 19-inch rack with good ventilation and resilient
mounting.
•
It is recommended that the area around the unit is kept free from dust and static
electricity.
•
All connections to the unit are on the rear side and available space for cable
connections and service must be provided.
3.2.5
Monitor
When installing the monitor, consider the following:
•
The unit is designed for installation in an indoor environment and for operation
within the temperature range. The best location is typically on a table in the
instrument room or on the bridge mounted close to the HMI Unit.
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Technical Description ...
Page 22: ...Seapath 320 8 Man_techn_seapath320 rev 1 ...
Page 42: ...Seapath 320 28 Man_techn_seapath320 rev 1 ...
Page 50: ...Seapath 320 36 Man_techn_seapath320 rev 1 ...
Page 86: ...Seapath 320 72 Man_techn_seapath320 rev 1 6 1 Processing and HMI Units ...
Page 87: ...Technical Description Man_techn_seapath320 rev 1 73 ...
Page 88: ...Seapath 320 74 Man_techn_seapath320 rev 1 6 2 Antenna bracket ...
Page 89: ...Technical Description Man_techn_seapath320 rev 1 75 6 3 MRU and mounting bracket ...
Page 90: ...Seapath 320 76 Man_techn_seapath320 rev 1 ...
Page 91: ...Technical Description Man_techn_seapath320 rev 1 77 6 4 MRU junction box ...
Page 95: ...Technical Description Man_techn_seapath320 rev 1 81 6 7 6 U cabinet dimensions ...
Page 96: ...Seapath 320 82 Man_techn_seapath320 rev 1 ...