922-20007052/1.2
37
Details
Get Status API
<Command>
<Operation>Get_Status</Operation>
</Command>
Get Status API response
<Response>
<Operation>Get_Status</Operation>
<Status>OK</Status>
<Message>Pinging</Message>
<Version>2.1.0</Version>
<Time>2016-09-13 15:22:21</Time>
</Response>
Set Mode
The
Set Mode
function allows you to set the optimal operating mode for your application.
Each mode has its own pre-defined characteristics, such as differing ranges, angular
resolutions, and pulse types.
Description
In the M3 software, the operating mode is set using the
Sonar Apps
menu (found at the
top of the presentation).
This API command requires a mode number (PRI Sequence ID). You can find a list of
mode numbers in the M3 Database Editor software.
Details
Set Mode API
<Command>
<Operation>Set_Mode</Operation>
<Mode>123</Mode>
</Command>
Related topics