342741/B
35
provided, the Synchronizing Unit will determine when the ping cycle is complete based
on the runtime settings in the K-Sync Application, i.e. calculated or fixed period is
selected.
Signals timing specification
Some of the timing and signal specifications with respect to the Synchronizing Unit
are listed below.
Table 3
Signals timing specification
Trigger display resolution (horizontal):
50 ms
Trigger display width:
10, 30 or 60 seconds
Max. trigger groups:
16
Signal latency (feedback signal to trigger output):
40 μs
Timing resolution of synchronization (calculated
or fixed trigger mode):
4 ms
Available signal inputs:
12, 24, 36 or 48 *)
Max systems/trigger outputs:
4, 8, 12 or 16 *)
Supported signal levels (inputs and outputs):
TTL and RS-232
Supported depth datagram input:
• Kongsberg EM: D, X, and E
• Kongsberg EA 500
• NMEA: DPT and DBS
*) Depending upon delivered configuration (4, 8, 12 or 16 systems).