alignment
NB! Some external sensors may have been set up to output
data referred to a location that differ from where it is physically
mounted. It is the x, y, z values for this location that must be
entered into the EM 710 Operator station.
8.1 Summary
The minimum requirements for alignment accuracy are given for
the various sensors in the following tables
WARNING
System performance will be reduced if the
requirements are not fulfilled. The calibration
value should not exceed the measurement
accuracies stated below.
TX array
Measurement accuracy
Position (x, y) [m]
± 0.05
Position (z) [m]
± 0.02
Pitch [deg]
± 0.05
Roll [deg]
± 0.20
Heading [deg]
± 0.10
RX array
Measurement accuracy
Position (x, y) [m]
± 0.05
Position (z) [m]
± 0.02
Pitch [deg]
± 0.20
Roll [deg]
± 0.02
Heading [deg]
± 0.10
Motion sensor
Measurement accuracy
Position (x, y) [m]
± 0.05
Position (z) [m]
± 0.05
Pitch [deg]
± 0.05
Roll [deg]
± 0.02
Heading [deg]
± 0.10
Heading sensor
Measurement accuracy
Heading [deg]
± 0.10
Positioning system (antenna)
Measurement accuracy
Position (x, y) [m]
± 0.05
Position (z) [m]
± 0.02
Water line
Measurement accuracy
Position (z) [m]
± 0.02
164851/C
97
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...