7.3.1.7 RX32 receiver board
Figure 27
RX32 Receiver Board with arrows
External connections
•
C43 - Connected to Ethernet switch board
The Ethernet cable is equipped with a standard RJ-45
connector. The Ethernet interface of the RX32 receiver board
must be connected to an Ethernet switch board. This interface
is used for all command input and sample data output. This
is normally the only cable connected to the RX32 receiver
board. It is provided by the manufacturer.
on page 142.
•
C44 - JTAG / For internal use only
This cable is connected to the JTAG slot to provide a JTAG
interface to the FGPA modules on the RX32 receiver board.
The signals of the JTAG slot are available at a 6-pin single
line header.
Note
This interface is only to be used by Kongsberg Maritime
personnel.
•
C45 - External synchronization (EXT SYNC) / For
internal use only
This cable is connected to the EXT SYNC slot for accurate
transmit synchronization with external equipment. The signals
of the EXT SYNC slot are available at a 10-pin double line
header.
Note
This interface is only to be used by Kongsberg Maritime
personnel.
68
164851/C
Summary of Contents for EM 710
Page 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Page 2: ......
Page 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Page 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Page 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Page 113: ...Installation drawings 164851 C 111 ...
Page 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Page 115: ...Installation drawings 164851 C 113 ...
Page 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Page 117: ...Installation drawings 164851 C 115 ...
Page 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Page 119: ...Installation drawings 164851 C 117 ...
Page 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Page 121: ...Installation drawings 164851 C 119 ...
Page 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Page 123: ...Installation drawings 164851 C 121 ...
Page 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Page 125: ...Installation drawings 164851 C 123 ...
Page 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Page 127: ...Installation drawings 164851 C 125 ...
Page 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Page 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Page 130: ...Kongsberg EM 710 128 164851 C ...
Page 132: ...Kongsberg EM 710 130 164851 C ...
Page 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Page 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Page 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...