148
472405/A
Using multi-diameter cable sealing
Cable sealing systems are available from several manufacturers, and multi-diameter
types are becoming increasingly popular due to their ease of use.
Prerequisites
Electrical installations can only be done by
certified electricians. All necessary tools and
instruments required must be available. The
installation shipyard must prepare detailed
drawings of the electrical system, and identify
each cable.
Illustration:
Sealing system example; the finished assembly
Context
Only a brief description of the sealing system
will be presented here. Further information
with relevant technical specifications and
installation descriptions must be obtained from
the manufacturer.
Roxtec modules (Image from Roxtec website)
The illustrations and examples here are provided by the following manufacturer:
Roxtec International AB
Box 540
S-371 23 Karlskrona, SWEDEN
•
KONGSBERG EM 2040 MKII Installation Manual
Summary of Contents for EM 2040 MKII
Page 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Page 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Page 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Page 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Page 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Page 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Page 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Page 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Page 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Page 247: ......
Page 248: ...2021 Kongsberg Maritime...