134
472405/A
RS-232 serial line used for DGNSS input
The EM 2040 MKII Portable Processing Unit has a dedicated interface for GNSS
correction using RS-422 or RS-232 serial communication.
A
Local connection
RJ45 connector
B
Connection on remote device
Unless otherwise specified, this cable must be provided
by the installation shipyard.
Minimum cable requirements
•
Conductors
: 2 x 3 x 0.2 mm²
•
Screen
: Overall braided
•
Voltage
: 30 V
•
Maximum outer diameter
: Defined by the plugs and/or the cable gland
We recommend using a shielded CAT-6A quality or better cable.