Remote control
The Processing Unit can be switched on/off with a remote switch. This switch is
connected to a 9–pin D-connector on the Processing Unit.
A
Local connection, male 9–pin
D-connector
B
Connection to remote lamp and
on/off switch
C
Female 9–pin D-connector
D
Male 9–pin D-connector
Minimum cable requirements
•
Conductors
: 3 x 0.5 mm²
•
Screen
: Overall braided
•
Voltage
: 60 V
•
Maximum outer diameter
: Defined
by the plugs and/or the cable gland
This cable must be provided by the
installation shipyard.