112
472405/A
Clock synchronization (1PPS) using a coax cable
The Processing Unit is equipped with a 1PPS signal input for clock synchronization.
A
Male BNC connector
B
Ground
C
1PPS signal
This cable must be provided by the installation
shipyard.
The 1PPS (one pulse per second) signal is normally
provided by a positioning system.
External synchronization cable
The Processing Unit (PU) is equipped with a connection for interface to an external
synchronization system.
This connection is used for interface to an external synchronization system (for example
K-Sync) used when multiple echo sounders are employed on the same vessel. The
external synchronization connector is located on the CBMF board of the processing
unit. The connector is RJ45 type.
A
Local connection The connector is RJ45 type.
Note
Pin 3 and 6 is used by Kongsberg Maritime only.
B
Connection on remote device
Unless otherwise specified, this cable must be provided by the installation shipyard.
KONGSBERG EM 2040 MKII Installation Manual
Summary of Contents for EM 2040 MKII
Page 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Page 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Page 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Page 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Page 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Page 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Page 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Page 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Page 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Page 247: ......
Page 248: ...2021 Kongsberg Maritime...