26
458122/B
7
Clean the threads in the transponder housing.
8
Feed the wires on the new connector through the connector hole.
9
Use Loctite 243 on the threads and apply activator.
10
Insert the connector.
11
Tighten the connector to 10 Nm.
12
Install the crimp terminals in the receptacle according to the cable drawing.
13
Put the battery and the PCB back in the tube.
14
Check and replace any damaged O-rings on the transducer before replacing it.
15
Connect the new connector and the transducer to the PCB.
16
Install the transducer.
Lubricating SEACON connectors
SEACON connectors require very little maintenance. They are designed to be used
in harsh environments and thus limited amounts of dirt and grit do not affect their
performance.
Context
It is recommended that, upon disconnecting or retrieving the system, the connectors be
cleaned, to storage (if possible, remate with dummy plugs). Prior to deployment the
following maintenance procedure is recommended:
Procedure
1
Demate the connector set.
cNODE MiniS LF Instruction Manual
Summary of Contents for cNODE MiniS LF
Page 1: ...458122 B September 2022 Kongsberg Maritime AS cNODE MiniS LF Transponder Instruction Manual ...
Page 34: ...34 458122 B cNODE MiniS 17 180 Ti dimensions cNODE MiniS LF Instruction Manual ...
Page 35: ...458122 B 35 cNODE MiniS 17 S Ti dimensions Drawing file ...
Page 36: ...36 458122 B TDR50V St dimensions cNODE MiniS LF Instruction Manual ...
Page 37: ...458122 B 37 TDR50V Ti dimensions Drawing file ...
Page 38: ...38 458122 B Transducer guard dimensions cNODE MiniS LF Instruction Manual ...
Page 39: ...458122 B 39 Floating collar dimensions Drawing file ...
Page 56: ... 2022 Kongsberg Maritime ...